BUREAU OF INDIAN STANDARDS · STANDARDS REGISTERRECORD ID: 09d537fa-c21b-4806-96d5-564f41ac90b9

IS 13428:2005

(Edition unknown)

PACKAGED NATURAL MINERAL WATER

Verified Record
● Full-Text Evidence Indexed (124 Passages)

Standard No.

IS 13428:2005

Category

product manual

Edition Year

unknown

Regulatory Status

Voluntary Reference

Certification

Scheme-I (ISI)

Issuing Authority

BIS

01

Specification Scope & Applicable Requirements

This Indian Standard establishes regulatory specifications, quality metrics, sampling procedures, and conformity criteria officially promulgated under the Bureau of Indian Standards Act.

02

Regulatory Context & Certification Architecture

Regulatory ParameterGazetted Record
Compulsory QCO StatusVoluntary Standard Reference
03

Sourced Documentary Evidence

124 Primary Passages
Gazetted SpecificationAnnex E -do- S -do- Once in two months · clause 7.3
Official Gazette Text

Sample of each size shall be tested by Test rotation so that all the sizes shall be tested in one operative period. 7.3 Stack load Test Annex F -do- R -do- One day production If the sample does not conform to the requirement the same day production shall be rejected. 7.4 Drop test Annex G -do- R -do- Every hour for each If the sample does not conform to the machine requirement, the licensee shall follow the criteria for acceptance and retesting as per clause G-3 of IS 15609:2005. If it still does not conform then the same day production shall be rejected. 7.5 Ink Adhesion of

Standard:IS 13428:2005
Gazetted SpecificationAnnex H IS 15609 R -do- One day production · clause 7.6
Official Gazette Text

If the sample does not conform to the Printed Pouches requirement the same day production shall be rejected. All rolls to be checked before using the same for making pouches. All such rolls which do not conform to the requirement shall be rejected. 7.6 Product resistance

Standard:IS 13428:2005
Gazetted Specification
Official Gazette Text

PM/13428/ 3 January 2023 उत्पाद मानुयल पैकेजबंद प्राकृतिक तमनरल जल - वितिवि IS 13428:2005 के अनुसार PRODUCT MANUAL FOR PACKAGED NATURAL MINERAL WATER ACCORDING TO IS 13428 : 2005 भारतीय मानक ब्य ू रो (नन ां य्ता म ू तया ु कन )विवनयम 8102 की स्कीम-I के तहत यह उत््ाद मान ां यल प्रमाणीकरणके प्रचलन मे रीवत और ्ारदवशिता के स ां स ु गता स ां वनवित करने के वलए सभी क्षेत्रीय/शाखा कायािलयों एि ु लाइसेन्स धाररयों द्वारा स ु दभि सामग्री के य् मे उ्योग वकया जाएगा। बीआईएस लाइसेन्स/प्रमाण ्त्र प्राप्त करने के इच्छ ां क भािी आिेदकों द्वारा भी इस दस्तािेज़ का उ्योग वकया जा सकता है। This Product Manual shall be used as reference material by all Regional/Branch Offices & licensees to ensure coherence of practice and transparency in operation of certification under Scheme-I of Bureau of Indian Standards (Conformity Assessment) Regulations, 2018 for various products. The document may also be used by prospective applicants desirous of obtaining BIS certification licence/certificate. 1. उत््ाद Product : IS 13428 : 2005 शीर्िक Title : Packaged Natural Mineral Water स ु शोधन स ु ख्या No. of Amendments : 11 2. Introduction and Salient changes in : Please refer Annex -A this version of the manual

Standard:IS 13428:2005
Gazetted Specification
Official Gazette Text

3. Product Specific Guidelines: a) Guidelines for processing : Please refer Annex –B Applications for grant of licence and change in scope of licence b) Guidelines for Surveillance : Please refer Annex – C c) Guidelines for actions in case of : Please refer Annex – D non-conformity including suspension and revocation of suspension of licence 4. ्रीक्षण उ्करणो की स ू ची List of Test Equipment : Please refer ANNEX –E 5. वनरीक्षण ि ्रीक्षण स्कीम Scheme of Inspection and Testing : Please refer ANNEX –F 6. Guidelines for Special Situations : Please refer ANNEX –G 7. Hygiene Checklist Please refer ANNEX –H (It shall be verified, filled up, duly- signed and uploaded as an attachment alongwith the Factory Test report. Hygiene assessment shall be done during all inspections(Preliminary inspection, Surveillance inspection, Verification inspection) 8. लाइसेन्स का कायिक्षेत्र / Scope of the Licence : PM/13428/ 3 January 2023 IS 13428:2005 के अन ु सार मानक म ु हर का उपयोग करने के लिए िाइसेंस लनम्नलिलित काययक्षेत्र के लिए प्रदान लकया जाता है: “Licence is granted to use Standard Mark as per IS 13428 : 2005 with the following scope: Name of the product Natural Mineral Water Varieties (Packaging)

Standard:IS 13428:2005
Gazetted Specificationclause 1.5
Official Gazette Text

Mention material (PE/PET/PVC/Glass etc.), type of containers (cup/bottles/jars etc.) and capacities in ml or litres (500 ml/1 litre/20 litres etc.) For example: PET Bottles of 500 ml, 1litre, 1.5 litre capacity and/or PET Jars of 20 litres capacity (any other pack sizes; containers for all pack sizes need to be in conformance to IS 15410 (as per latest amendment) BUREAU OF INDIAN STANDARDS Manak Bhawan, 9, Bahadur Shah Zafar Marg, New Delhi – 110002 PM/13428/ 3 January 2023

Standard:IS 13428:2005
Gazetted SpecificationAnnexure A
Official Gazette Text

Salient changes in this version of the manual 1. The first edition Manual for Packaged Water, which provided internal guidelines to BIS Certification officers for certification of Packaged Drinking Water (Other Than Packaged Natural Mineral Water) (PDW) and Packaged Natural Mineral Water (PNMW) was issued in 2005. Following changes in the standard and feedback obtained during certification, the second and third editions of this Manual were issued in 2007 and 2013, respectively. 2. Following the revision of the BIS Act, 1986 as the BIS Act, 2016 in March 2017 and subsequent issue of general guidelines for certification based on the Act and regulations framed thereunder, it was decided to prepare a Scheme of Inspection and Testing (SIT) as per the provisions of the new regulations for both PDW/PNMW. Accordingly, SITs for both PDW and PNMW were issued in 2018-19. 3. Subsequently, it was also felt that the Manual for Packaged Water also needs to be revised to align with the provisions of the existing Indian Standard, and the BIS Act, with a view to consolidate the various guidelines for certification of packaged water in a single, user-friendly document. Accordingly, in line with the practice

Standard:IS 13428:2005
Gazetted SpecificationAnnexure A
Official Gazette Text

for other products, separate product manuals for PDW and PNMW were framed. This document pertains only to PNMW manual, the PDW manual has been issued separately. 4. The salient changes in this version of the PNMW manual are as follows: i. The manual has been updated with respect to various amendments to IS 13428 (upto Amendment No. 11) and guidelines issued from time to time. ii. The list of test equipment has been updated as per revised test methods wherever applicable; and the list of test equipment for Uranium has been included. iii. In line with CMD-2 circular dated 22-03-2022 regarding testing of Pesticide Residues in Packaged Natural Mineral Water as per IS 13428:2005, it has been specified that out of all the samples drawn for factory/market surveillance in a year, only one sample may be got tested for pesticide residues. The same shall be clearly indicated on the test requests generated by BOs/outsourced agencies. However, if a sample fails in the requirement of Pesticide Residues, then the next 3 consecutive samples (factory/market) of that licence shall be tested for all tests including Pesticide Residues (except Radioactive residues), till the 3 consecutive samples are found conforming to all

Standard:IS 13428:2005
Gazetted SpecificationAnnexure A · clause 16.09
Official Gazette Text

requirements tested including pesticide residues. 5. The salient features of the erstwhile product manual(PM/13428/2, July 2020), which remains in vogue and are to be followed: i. As per Guidelines for Grant of Licence (GoL) as per the conformity assessment Scheme – I of Schedule – II of BIS (Conformity Assessment) Regulations, 2018, the provision for grant of licence under option 2 (simplified procedure) has been excluded. ii. It has been specified that the compliance of source of water and process adopted by the manufacturer for treatment/disinfection of the water shall be verified and details thereof reported during preliminary inspection. iii. In line with CMD-2 circular dated 16.09.2019 regarding testing of market samples of reusable containers of PNMW, it is specified that separate samples of containers need not be drawn during factory and market surveillance for testing. The possible tests on containers will be carried out on PM/13428/ 3 January 2023 the containers of the samples of Natural Mineral Water drawn for chemical/microbiological/other tests during factory and market surveillance. iv. It is a l s o permitted that at the grant of licence stage and during operation of the licence stage, for

Standard:IS 13428:2005
Gazetted SpecificationAnnexure A
Official Gazette Text

inclusion of containers sizes, the manufacturer may offer only (at least) one sample of packaged natural mineral water in any one variety of packaging along with conforming tests reports issued by BIS recognized labs for the other varieties of packaging/containers intended to be covered in the scope of the licence. (Test reports may not be required in case containers are ISI marked). v. It was also specified that although in case of water samples, consecutive non-conformity will attract suspension, in case of non-conformity of containers, suspension will be attracted only in case the same variety of container (i.e. same material, type and capacity of container) fails more than two times consecutively. However, first failure will attract suspension in case of parameters concerning radioactive residues. vi. As per the previous Water Manual, if a fresh application has been submitted after closure of earlier application or expiry/cancellation of earlier licence and the closure of application/licence was for reasons other than failure in radioactive residues, fresh sample of water need not be drawn for testing of radioactive residues, if evidence is available that the source of raw water remained the

Standard:IS 13428:2005
Gazetted SpecificationAnnexure A
Official Gazette Text

same as that in earlier application/licence, provided that radioactive residue TR of the sample drawn by BIS during verification visit passes and is not older than five years. The earlier test reports of sample drawn by BIS (not older than five years) shall be accepted within a period of five years. This provision has been removed in this version since present regulations/guidelines do not permit acceptance of applications based on old test reports. vii. IS 11984 has been specified as a reference Indian Standard for glass bottles. If any manufacturer intends to use glass bottles for packaging, it shall be included in the licence. The separate processing line for filling the glass bottles may be verified by BIS during the next visit and necessary steps in the process for ensuring sterility of bottles may be adopted like steam sterilizing, hot water rinsing, UV sterilization or combination thereof. In case of lug caps containing plastic lining, food grade certificate or OSL report for migration testing may be accepted. viii. Manufacturers need not maintain separate chemists and microbiologist and alternatively, may keep even one testing person, in case he/she is found competent for both chemical and microbiological

Standard:IS 13428:2005
Gazetted SpecificationAnnexure A
Official Gazette Text

testing. This shall be duly recorded in PIR. ix. Guidelines for special situations faced in certification of packaged water have been addressed (Annex G) covering aspects like change in source of raw water, shelf life, brand name/label approvals. It has been specified that in case the brand name/trademark submitted by the firm is a registered brand name/trademark, no objection to its use shall be raised even if the brand name/trademark is found to be in non-compliance to Clause 8 of IS 13428. However, in such a case, the Head BO concerned shall communicate the details of such cases to CMD-2 for taking up with the concerned authorities. PM/13428/ 3 January 2023

Standard:IS 13428:2005
Gazetted SpecificationAnnex B · clause 2.1
Official Gazette Text

Product Specific Guidelines for processing applications for grant of licence and change in scope of licence B-1. Application for grant of licence i. Domestic manufacturers of PNMW shall apply for grant of licence for his unit online through the Manakonline system as per the provided application format i.e. as per Form V as specified in Scheme I of Schedule II of BIS (Conformity Assessment Regulations), 2018. (Presently foreign applications under FMCS are being processed on offline mode). ii. Applications will only be accepted under Option 1 (Normal procedure), i.e. after receipt of the application and ensuring completeness of the application, a visit will be paid by BIS to the factory of the applicant for assessment of the manufacturing infrastructure, production process, quality control, testing capabilities, assessment of hygiene conditions and sample will be drawn for testing in third party laboratory. B-2 Preliminary Inspection B-2.1 During preliminary inspection, the documents/aspects as mentioned in general GoL guidelines shall be verified and the observations recorded in the Preliminary Inspection Report in the format circulated by CMD.

Standard:IS 13428:2005
Gazetted SpecificationAnnex B · clause 2.2
Official Gazette Text

B-2.2 The actual factory layout shall be verified against the layout submitted with application. The layout should clearly indicate the different locations preferably including the following: a) Location of source of raw water and its entry point, pipeline etc. b) Plant for the manufacture of the product (with various stages) c) Filling/packing areas, change room, toilet(s), e) Entry/exit with indications of double door/door closures/Air curtains wherever provided f) Stores for packaging material and finished product g) Laboratory h) Actual boundary/perimeter of the establishment i) If the premises are also used for residential quarters/other purposes, then specific mention of the same be made with identified locations. B-2.3 As product is under mandatory certification, it is unlikely to be in “production” during PI. It is therefore essential to get some production & filling/packing done as ‘Trial Batch’ during the visit and then make comments on the firm’s capability for the same. B-2.4 It should be clearly reported in the PIR as to whether the filling/packaging adopted are manually operated or automatic. It may be noted that the plastic cups, tumbler, pouch bottles are required to be filled

Standard:IS 13428:2005
Gazetted SpecificationAnnex B · clause 2.5
Official Gazette Text

only through automatic machine. However, jars maybe filled manually also. B-2.5. In addition, the following product specific aspects shall also be verified and observations recorded in the Preliminary Inspection Report or in an Annexure to that report: PM/13428/ 3 January 2023 i. Availability of all manufacturing facilities including filling and/or packaging machinery for the varieties applied for to be verified and observations recorded; ii. Compliance to hygienic practices as per Annex B of IS 13428, to be verified and observations to be recorded as per Hygiene Checklist (as per Annex-H). iii. As per Cl 3.1 of IS 13428:2005, Natural Mineral Water is: a) is obtained directly from natural or drilled sources from underground water-bearing strata; b) it is characterized by its content of certain mineral salts and their relative proportions and the presence of trace elements or of other constituents; c) of the constancy of its composition and the stability of its discharge and its temperature, due account being taken of the cycles of minor natural fluctuations; d) it is collected under conditions which guarantee the original microbiological purity and chemical composition of essential components; e) it is packaged close to the point of emergence of the source with particular

Standard:IS 13428:2005
Gazetted SpecificationAnnex B · clause 4.1
Official Gazette Text

hygienic precautions; f) it is not subjected to any treatment other than those permitted under Cl 4.1 of IS 13428. Compliance to Cl 3.1 a) to f) shall be ensured and reported in the Preliminary Inspection report. iv. As per Cl.3.1.6 of IS 13428:2005, Natural Spring water is natural mineral water which is derived from an underground formation from which water flows naturally to the surface of the earth at an identified location. Spring water shall be collected only at the spring or through a borehole tapping the underground formation feeding the spring. There shall be a natural force causing the water to flow to the surface through an orifice. Compliance to Cl 3.1.6 and 6.4 shall be ensured and reported in the preliminary inspection report in case manufacturer claims the natural mineral water as Natural spring water. v. The transport of natural mineral water in bulk containers for packaging or any other process before packaging is prohibited. vi. Natural mineral water shall have the constancy of its composition and the stability of its discharge and temperature, due account being taken of the cycles of minor natural fluctuations. Evidence for constancy of water composition at source on account of cycles of minor natural fluctuations

Standard:IS 13428:2005
Gazetted SpecificationAnnex B
Official Gazette Text

during different seasons in a year shall comprise of the following: a. Undertaking for submission of Test report (from any BIS approved OSL) of all the major seasons (over a period of one year) for all the major physicochemical parameters, complying to the requirements of IS 10500; b. Record of temperature at discharge point/ point of emergence (by manufacturer); and c. Report from the Hydrogeologist covering genesis of natural mineral water; period of its residence in the ground; chemical, physical and radiological qualities; and the risk of pollution vii. Availability of required testing facilities, as per the ISS should be verified and recorded. The test equipment should have valid calibration on the day of the visit. Calibration should be done from NABL accredited laboratory or any other laboratory provided traceability to NPL is established through the calibration certificates. Calibration of Analytical Balance, temperature indicators, pressure gauge of autoclave and spectrophotometer (internal/in-house or from an outside lab) is PM/13428/ 3 January 2023 considered necessary at least once a year. Indicative List of test equipment and chemicals required

Standard:IS 13428:2005
Gazetted SpecificationAnnex B · clause 3.1
Official Gazette Text

for testing of Natural Mineral Water is given at Annex E for guidance. Status of test equipment calibration observed from calibration certificates should be certified. viii. Testing person(s) shall be science/engineering graduate from disciplines such as chemistry/chemical engineering/ microbiology/ biotechnology/ biochemistry/ food technology/ botany and other biological/ life sciences. Engineering graduates from disciplines such as chemical engineering may also be engaged as testing persons. Availability of testing person(s), his/her competence, qualifications and experience shall be verified and reported. One testing personnel may be allowed in case he/she is found competent for both chemical and microbiological testing and if so, this shall be duly recorded in Inspection Report. B-3 Factory testing B-3.1 One sample of the product shall be tested in the factory during the preliminary inspection for preferably following requirements: Description, Colour, Odour, Taste, Turbidity, Total Dissolved Solids (TDS) by gravimetric method as per IS 3025(Part-16), pH, Chloride and Alkalinity. B-3.2 In case any non-conformity is observed during factory testing, no sample shall be drawn for

Standard:IS 13428:2005
Gazetted SpecificationAnnex B · clause 4.1
Official Gazette Text

independent testing in third party lab. (Please refer Annex D for guidelines to be followed in case of non conformity) B-4 Sample for Independent Testing B-4.1 If the sample passes in factory testing, sample of Natural Mineral Water shall be drawn and sent for complete testing for all requirements of the Indian Standard. The following details should be mentioned in the test request (generated through Manakonline): i. Specify if it is Natural Spring Water (as per Cl. 3.1.6 o IS 13428:2005) ii. Date of manufacture/packing and batch number; iii. Expiry/Use by; iv. Quantity (number of containers and total quantity of Natural Mineral Water in litre or milliliter), v. Type, material and capacity of containers vi. Declared wall thickness of container(s)/width of film of pouch B-4.2 In case of foreign manufacturers, test report through LIMS is not applicable, till applicants/licencees under FMCS are brought on online mode, integrated with LIMS. B-4.3 However, in case the manufacturer intends to cover more than one variety of packaging in the scope of licence, he need not offer samples of each variety of packaging during the factory visit (preliminary inspection) for testing in third party lab. However, it shall be ensured that the manufacturing facilities for

Standard:IS 13428:2005
Gazetted SpecificationAnnex B
Official Gazette Text

manufacturing other packing sizes (if applicable) like moulding machines, etc, are available. He may offer sample of the product in at least one variety of packaging, along with either: a. Conforming tests reports issued by BIS recognized labs (through LIMS only) for the other varieties of packaging/containers intended to be covered in the scope of the licence. These test reports issued through LIMS, shall not be older than 90 days on the date of submission of application. PM/13428/ 3 January 2023 In case an application is received for more than one variety of container and the variety of the container drawn during preliminary inspection, does not conform to the requirements of the Indian Standard, however the product (Packaged Natural Mineral water) is found conforming to all the requirements of the Indian Standard, then the application is to be processed for Grant of Licence for all those varieties of container packaging, whose conforming test report has been submitted with the application. Under such circumstances, the variety of container, which has not been found conforming to the requirements of relevant Indian Standard, shall be excluded from the scope. Further there may be a situation when applicant has applied for one variety only and the container is

Standard:IS 13428:2005
Gazetted SpecificationAnnex B
Official Gazette Text

found failing but the product (PNMW) is passing. Under such circumstances, only the improved sample of the container as offered by the manufacturer, maybe tested for conformity to the requirements of the relevant Indian Standard. . OR b. In case the applicant uses/intends to use ISI Marked Plastic Containers as per IS 15410 or ISI Marked polyethylene flexible pouches as per IS 15609 or ISI Marked Paper based multilayer laminated/extruded composite cartons as per IS 17753 or ISI marked aluminum cans as per the finalized draft of Indian Standard 'Aluminum cans for packaged natural mineral water and packaged drinking water — Specification' [Doc: PGD 38 (20182)], the manufacturer may submit a consent letter from the BIS licensed manufacturer of the container, that he has agreed to supply ISI Marked containers for the required varieties (to be explicitly mentioned in the letter) to the applicant firm. In that case test reports from third party labs need not be submitted for those varieties. The letter from BIS licensed manufacturers shall not be older than 90 days on the date of submission of application. The test certificates of the containers issued as per relevant Indian Standard(s) by the BIS licensed manufacturer

Standard:IS 13428:2005
Gazetted SpecificationAnnex B · clause 4.4
Official Gazette Text

is required to be submitted at the time of submission of application / before inspection, for examination by BIS. B-4.4 In case the applicant is adopting more than one type of processes/sources of raw water, separate samples shall be drawn for each process/source. B-4.5 The sample quantity to be sent to the third-party lab for testing is as follows: i) Natural Mineral Water a) For all parameters other than radioactive residues - A sample containing approximately 18 litres of Natural Mineral Water (NMW) in two parts is adequate, if packed in 1 liter or smaller containers but in case the samples are available in large size packages, minimum two such packages are required as microbiological laboratory needs separate sample for ensuring aseptic handling. For example: Capacity of the container Number of containers to be drawn (cup/bottle/jar) in litres 1 18 2 9 5 4 10 2 20 2 25 2 PM/13428/ 3 January 2023 For Pouches: 2 bags/cartons each containing total of atleast 100 pouches + Film. b) For Parameters concerning Radio-active Residue In addition to the above, sample shall also be drawn for testing parameters concerning radioactive residues. A sample of 10 litres is adequate. (ii) Sample of packaging material (containers) ::

Standard:IS 13428:2005
Gazetted SpecificationAnnex B
Official Gazette Text

Capacity of the container (cup/bottle/jar) in ml/L Number of containers (including caps) to be drawn 200ml 30(empty with caps) + 9(filled)+40 caps 250ml 27 (empty with caps) + 9 (filled) + 40 (caps) 500ml 24 (empty with caps) + 9 (filled) +40 caps 1 liter 21 (empty with caps) + 9 (filled) + 40 caps 2 litre 18 Empty (with caps) + 8 (filled) + 40caps 5 litre and above 7 Empty (with caps) + 8 (filled) + 25 caps Pouches: 1 bag of 50 filled pouches + 18 meter film+ 10 Nos. of Preformed pouches of dimension 125 mm X 200 mm. Cup/Glass along with peelable seal: 37 (Empty) + 15 (filled) + 18 meter film of peelable seal + 8 preformed pouches of 125 mm x 200 mm of peelable seal. Note 1: The pouches shall be made in the presence of BIS officer, during inspection, and, may be printed with only details like batch number, date of manufacturing, Expiry/Use by,, capacity, using ink to be used by the manufacturer for marking on the pouches. This will facilitate testing of pouches for ink adhesion test and product resistance test. This is being allowed as manufacturer cannot get the pouch film rolls printed with all other details such as Standard Mark etc. before the GOL. Note 2: IS 11984 has been specified as a reference Indian Standard for glass bottles/tumbler, however such

Standard:IS 13428:2005
Gazetted SpecificationAnnex B · clause 5.1
Official Gazette Text

containers need not be tested. However, if any manufacturer intends to use such container, it shall be included in the licence.. The separate processing line for filling the glass bottles may be verified by BIS during the next surveillance visit and necessary steps in the process for ensuring sterility of bottles may be adopted like steam sterilizing, hot water rinsing or combination thereof. In case of lug caps containing plastic lining, food grade certificate or OSL report for migration testing may be accepted. Note 3: Effort shall be made, as far as possible, to send samples without the manufacturer’s identification and/or markings. Any label and/or manufacturer's identification from the bottles/Jars shall be removed or defaced. Note 4: The manufacturer’s declaration with respect to the minimum wall thickness (Top/Middle/Bottom) of the container and shelf life of product, shall be obtained and the same to be mentioned in the test request B-5 Change in Scope of Licence B-5.1 For the purpose of certification of PNMW, change in scope of licence pertains only to addition/deletion of the varieties of packaging covered in the scope of the licence.

Standard:IS 13428:2005
Gazetted SpecificationAnnex B · clause 5.2
Official Gazette Text

B-5.2 In case a licensee intends to add new varieties of packaging in scope of licence, he shall submit an application in the Form – XIV along with requisite fee and relevant documents. PM/13428/ 3 January 2023 B-5.3 In addition, he shall submit conforming third party lab test report(s) of samples of each variety of the packaging (i.e. each material (PET/PE etc.), form or type (cup/bottle/jar) and capacity in ml or litres) intended to be added to the scope of licence. B-5.4 In addition to these guidelines, Guidelines for Grant of Licence (GoL) and Change in Scope of Licence (CSoL) as per the conformity assessment Scheme – I of Schedule – II of BIS (Conformity Assessment) Regulations, 2018 issued by CMD-1 shall be followed. PM/13428/ 3 January 2023

Standard:IS 13428:2005
Gazetted SpecificationAnnexure C · clause 1.1
Official Gazette Text

Guidelines for Surveillance Surveillance consists of two activities in case of Natural Mineral Water certification i.e. surveillance visits at factory premises (which includes testing of sample drawn from factory) and drawl of samples from the market for third party lab testing. Product Specific guidelines for these are as follows: C-1. Factory Surveillance C-1.1 During factory surveillance visit, the compliance to the requirements of the SIT and ISS shall be verified and the observations recorded in the Report of Periodic Inspection in the format circulated by CMD (General Format applicable for all products), C-1.2 However, in addition, the following product specific aspects shall also be verified and observations recorded in the Report of Periodic Inspection or in an Annexure to that report: i. Any change in manufacturing facilities including filling and/or packaging machinery for the varieties applied for to be verified and observations recorded; ii. Compliance to hygienic practices as per Annex B of IS 13428 to be verified and observations to be recorded as per Hygiene Checklist at Annex-H of this product manual. iii. Any change in Source of Water shall be checked for and reported. Any observations

Standard:IS 13428:2005
Gazetted SpecificationAnnexure C
Official Gazette Text

including non-compliance to IS requirements to be reported. iv. Any observations including non-compliance to IS requirements to be reported. v. Any change in nature of treatments processes to be verified and observations including compliance thereon to be reported (This may be mentioned in the process flowchart submitted.) vi. Availability of required testing facilities, as per the ISS should be verified and recorded. Any change in the test facilities should be checked for and reported. The test equipment should have valid calibration on the day of the visit. Calibration should be done from NABL accredited laboratory or any other laboratory provided traceability to NPL is established through the calibration certificates. Calibration of Analytical Balance, temperature indicators, pressure gauge of autoclave and spectrophotometer (internal/in-house or from outside lab.) is considered necessary at least once a year. Indicative List of test equipment and chemicals required for testing of Natural Mineral Water is given at Annex E for guidance. Status of test equipment calibration observed from calibration certificates should be reported. vii. Any change in testing person(s) should be checked for and reported along with

Standard:IS 13428:2005
Gazetted SpecificationAnnexure C · clause 2.1
Official Gazette Text

comments on the competence, qualifications and experience. viii. Compliance to requirements of SIT shall be verified and observations reported. C-2 Factory testing PM/13428/ 3 January 2023 C-2.1 One sample of the product shall be tested in the factory during the preliminary inspection for preferably following requirements: Colour, Odour, Taste, Turbidity, pH, Chloride, Alkalinity. C-2.2 In case any non-conformity is observed during factory testing, no sample shall be drawn for independent testing in third party lab. (Please refer Annex D for actions to be taken in case of non- conformity) C-3 Sample for Independent Testing C-3.1 If the sample passes in factory testing, sample of Natural Mineral Water shall be drawn and sent for complete testing for all requirements of the Indian Standard IS 13428:2005 except the parameters concerning radioactive residues. However, out of all the samples drawn for factory/market surveillance in a year, only one sample may be got tested for pesticide residues, which is required to be clearly indicated on the test requests generated by BOs/outsourced agencies. But, if a sample fails in the requirement of Pesticide Residues, then the next 3 consecutive

Standard:IS 13428:2005
Gazetted SpecificationAnnexure C · clause 3.1.6
Official Gazette Text

samples (factory/market) of that licence shall be tested for all tests including Pesticide Residues(except Radioactive residues), till the 3 consecutive samples are found conforming to all requirements tested including pesticide residues. The following details should be mentioned in the test request (generated through Manakonline): i. Specify if it is Natural spring water (as per Cl 3.1.6 of IS 13428:2005) ii. Date of manufacture/packing and batch number; iii. Expiry/Use by or Best Before Days/Months from the date of Packaging/Manufacture ; iv. Quantity (number of containers and total quantity of Natural Mineral Water in litre or milliliter), v. Type, material and capacity of containers vi. Declared wall thickness of container(s)/width of film of pouch vii. ‘All tests/All Chemical tests/All Possible tests, except Pesticide Residues and Radioactive Residues’ (where pesticide residue is not required to be tested) And All tests/All Chemical tests/All Possible tests, including Pesticide Residues, but excluding Radioactive Residues (where pesticide residue is required to be tested) ‘ C-3.2 In case the applicant is adopting more than one type of processes/sources of raw water, samples shall

Standard:IS 13428:2005
Gazetted SpecificationAnnexure C · clause 3.3
Official Gazette Text

be drawn for each process/source by rotation during factory surveillance. C-3.3 The sample quantity to be sent to the third party lab for testing is as follows: i) Natural Mineral Water For all parameters other than radioactive residues - A sample containing approximately 18 litres of packaged water (NMW) in two parts is adequate, if packed in 1 liter or smaller containers but in case the samples are available in large size packages, minimum two such packages are required as microbiological laboratory needs separate sample for ensuring aseptic handling. . Details of pack sizes to be drawn are as given above, under clause B-4.5 (i)(a) For Pouches: Details of pack sizes to be drawn are as given above, under clause B-4.5 (i)(a) C-4 Market Surveillance PM/13428/ 3 January 2023 C-4.1 While obtaining samples of Natural Mineral Water from the market, it should be ensured that the samples being drawn are bearing genuine ISI mark. This may be done by checking the licence number printed on the label. In case it is found that the ISI mark is spurious, the sample shall not be drawn for testing and suitable action should be initiated for further investigation. C-4.2 For sending the market sample to the lab for testing, the following details should be mentioned in

Standard:IS 13428:2005
Gazetted SpecificationAnnexure C · clause 3.1.6
Official Gazette Text

the test request (generated through Manakonline): i. Specify if it is Natural Spring water (as per Cl 3.1.6 of IS 13428:2005) ii. Date of manufacture or packaging’ and ‘Expiry/Use by; iii. Best Before Date(optional); iv. Quantity (number of containers and total quantity of Natural Mineral Water in litre or milliliter), v. Type, material and capacity of containers C-4.3 Separate samples of containers need not be drawn during market surveillance for testing. The possible tests on containers (including transparency) will be carried out on the containers of the samples of Natural Mineral Water drawn for testing requirements as per IS 13428 excluding PR and RAR. This shall be mentioned on the test request. C-4.4 The sample quantity to be sent to the third-party lab for testing is as follows: i) Natural Mineral Water For all parameters other than radioactive residues – A sample containing approximately 18 litres of Natural Mineral Water (NMW) in two parts is adequate, if packed in 1 liter or smaller containers but in case the samples are available in large size packages, minimum two such packages are required as microbiological laboratory needs separate sample for ensuring aseptic handling. For example:

Standard:IS 13428:2005
Gazetted SpecificationAnnexure C
Official Gazette Text

Capacity of the container Number of containers to be drawn (cup/bottle/jar) in litres 1 18 2 9 5 4 10 2 20 2 25 2 For Pouches: 2 bags of 100 pouches each + Film. A sample of 4 bags shall be drawn in case each bag contains 50/60 pouches. PM/13428/ 3 January 2023

Standard:IS 13428:2005
Gazetted SpecificationAnnexure D · clause 1.1
Official Gazette Text

Guidelines for actions in case of non-conformity including suspension and revocation of suspension of licence D-1.1 Guidelines for Suspension (SUS) and Revocation of Suspension (ROS) of Licence – For Scheme - I of Schedule - II of BIS (Conformity Assessment) Regulations, 2018 issued by CMD-1 shall apply in case of Natural Mineral Water. In addition, the following product specific guidelines will apply. Wherever the general and product-specific guidelines are in conflict, the product specific guidelines will take precedence. D-1.2 Non Conformity of Samples Non-conformity of containers/packaging material shall not be treated at par with non-conformity of Natural Mineral Water, since the criticality of the former is lower. Accordingly, non-conformity in case of Natural Mineral Water and containers/packaging material shall be treated separately as follows: D-1.2.1 Non-conformity of Natural Mineral Water (IS 13428) i) Suspension shall be imposed in the event of consecutive non-conformity of samples of Natural Mineral Water. However, suspension shall be imposed on first non-conformity itself if the non-conformity of Natural Mineral Water is in respect of parameters concerning radioactive

Standard:IS 13428:2005
Gazetted SpecificationAnnexure D
Official Gazette Text

residues or pesticide residue or toxicity. ii) For other situations, in case of first non-conformity, the non-conformity shall be communicated to the licensee through email/speed post/IT software with a copy of the test report (as per template given in Annex I of SUS/ROS guidelines). The licensee shall be advised to take corrective action and submit reply with supporting evidence, as applicable, within 30 days (one month) of the date of communication. iii) When the corrective actions as mentioned at para ii above, are received within 30 days (one month), the DO shall put up the case to the Head BO for nominating an officer for verification of the corrective actions preferably within 90 days through a surveillance inspection. iv) If during the surveillance inspection, the sample is non-conforming in factory testing, it shall be treated as consecutive non-conformity and suspension shall be imposed and actions for communication of suspension as per para 10 of SUS/ROS guidelines shall be taken. v) However, if corrective actions as mentioned at para ii are not received within 30 days (one month), the case may be processed for imposition of suspension. PM/13428/ 3

Standard:IS 13428:2005
Gazetted SpecificationAnnexure D · clause 1.2.2
Official Gazette Text

January 2023 D-1.2.2 Non-conformity of container or packaging material (IS 15410 etc) i) First non-conformity a) For containers/packaging material, in case of first non-conformity, the non-conformity shall be communicated to the licensee through email/speed post/IT software with a copy of the test report (as per template given in Annex I of SUS/ROS guidelines). The licensee shall be advised to take corrective action and submit reply with supporting evidence, as applicable, within 30 days (one month) of the date of communication and offer improved samples for testing. b) When the corrective actions as mentioned at para (a) above, are received within 30 days (one month), the DO shall put up the case to the Head BO for nominating an officer for verification of the corrective actions preferably within 90 days through a surveillance inspection. c) Since factory testing of containers during surveillance visit may not be feasible in most cases as most manufacturers are procuring containers from outside and do not have in- house testing facilities, the corrective action shall be verified from documents etc as far as possible and improved sample of container shall be drawn for testing for all requirements

Standard:IS 13428:2005
Gazetted SpecificationAnnexure D
Official Gazette Text

of the standard (i.e. IS 15410) in third party lab during surveillance visit. ii) Second non-conformity (First consecutive non-conformity) a) Non-conformity is to be considered as consecutive in case of containers only when the same variety of containers (i.e. the same material, type/form and capacity) is found to be non-conforming consecutively and hence suspension shall not be imposed in the first instance of consecutive non conformity in case of container. The non-conformity shall be communicated to the licensee through email/speed post/IT software with a copy of the test report (as per template given in Annex I of SUS/ROS guidelines). The licensee shall be advised to take corrective action and submit reply with supporting evidence, as applicable, within 30 days (one month) of the date of communication and offer improved samples for testing. b) When the corrective actions as mentioned at para (a) above, are received within 30 days (one month), the DO shall put up the case to the Head BO for nominating an officer for verification of the corrective actions preferably within 90 days through a surveillance inspection. c) Since factory testing of containers during surveillance visit may not be feasible in most

Standard:IS 13428:2005
Gazetted SpecificationAnnexure D
Official Gazette Text

cases as most manufacturers are procuring containers from outside and do not have in- house testing facilities, the corrective action shall be verified from documents etc as far as possible and improved sample of container shall be drawn for testing for all requirements of the standard (i.e. IS 15410) in third party lab during surveillance visit. PM/13428/ 3 January 2023 iii) Third non-conformity (Second Consecutive Non-Conformity) Suspension shall be imposed in case of second instance of consecutive non-conformity of the same variety of containers i.e. third consecutive non-conformity of same variety of container and actions for communication of suspension as per para 10 of SUS/ROS guidelines shall be taken. iv) Suspension shall also be imposed in case improved sample offered after second non conformity (first consecutive non-conformity) fails in factory or independent testing or if licensee fails to confirm corrective actions within 30 or days and/or offer improved sample during the visit, and actions for communication of suspension as per para 10 of SUS/ROS guidelines shall be taken v) Revocation of suspension shall be done as per the general Guidelines for Suspension (SUS)

Standard:IS 13428:2005
Gazetted SpecificationAnnexure D · clause 2.1
Official Gazette Text

and Revocation of Suspension (ROS) of Licence. D-2 Unsatisfactory performance D-2.1 In case the following situations are observed, it shall be treated as major modification in process without prior evaluation of the Bureau and shall attract suspension on the first instance itself: i) Change of source of raw water without evaluation of the Bureau. ii) Modification in the process with or without any change in raw water source, without prior evaluation of the Bureau. (Any addition or deletion of processing machinery eg. Tanks/Filling machine, etc for capacity enhancement or otherwise, which does not change the overall manufacturing process, will not constitute as modification in the process. A declaration regarding the same may be taken during surveillance in Form-I.) PM/13428/3 January 2023

Standard:IS 13428:2005
Gazetted SpecificationAnnexure E · clause 6.2
Official Gazette Text

LIST OF TEST FACILITES A-ORGANOLEPTIC AND PHYSICAL REQURIMENTS SI. Tests Clause Ref. of Referred Method of Test /Equipment /Apparatus Chemical/Regents No. IS 13428:2005 Tests & Limit of Detection (1) (2) (3) (4) (5) (6) 1. Colour 6.2, Sl No. i) of IS 3025 (Part 4) • Potassium chloroplatinate Table 1 • Cobaltous chloride, i) Platinum crystalline cobalt (Visual Nessler cylinders,50 ml • Conc. Hydrochloric acid Comparison Centrifuge or filter assembly, functional • Distilled water method) pore size 0.45μm ii) Spectrophoto- • Spectrophotometer,400-700 nm with • Conc. Sulphuric acid metric method 10 mm absorption cell • Filteration system consisting of • Sodium hydroxide filteration flask with side tubes. • Crucible holder • Micrometallic filter crucible, pore 40 μm • Calcined filter aid (Celite 505 or equivalent • Vacuum system • Refrigerator (recommended) • pH meter • Centrifuge 2. Odour 6.2, SI No, ii) of IS 3025 (P 5 ) • Wide mouth glass stoppered bottles • Odour free distilled water (or Table 1 (approx.1 lit . capacity) distilled water and column of granulated activated carbon) • Hydrochloric acid 3. Taste 6.2, Sl. No. iii) IS 3025 (P 8) Breaker (50ml) Taste and Odour free water of table 1 Water bath 2000 mg/l solution of sodium

Standard:IS 13428:2005
Gazetted SpecificationAnnexure E · clause 6.2
Official Gazette Text

Thermometer chloride 4. Turbidity 6.2, Sl. No. iv) IS 3025 (P 10) • Sample tubes • Distilled water of Table 1 • Turbidity meter • Hexamethylene Tetramine PM/13428/3 January 2023 • Volumetric flasks (100 ml) • Hydrazine sulphate • Membrane filter with pore size not more than 0.45 μm 5. Total 6.2, Sl No. v) of IS 3025 (P 16) • Filter: dissolved Table 1 • Filtering Assembly (suitable for type of solids filter selected) • Drying oven (180 ± 2 ̊C) • Desiccator • Analytical balance (200 g capacity, LC 0.1 mg) • Pipettes • Evaporating dish • Magnetic stirrer, recommended • Conductivity meter. 6 pH 6.2, Sl No. vi) of IS 3025 (P 11) • pH meter – with glass and reference • Standard pH Buffer Table 1 electrode (saturated calomel) l.c 0.1 solutions/tablets (Buffer • Magnetic stirrer with poly tetra fluoro tablets pH 4, pH 7, pH ethylene coated stirring bar 9.2) (Minimum two different • Thermometer (l.c. 0.5°C values) • Beakers OR • Distilled water • Borax (for Borax buffer) • Potassium dihydrogen phosphate, Sodium hydrogen phosphate and oven (for phosphate buffer) • Potassium hydrogen tartarate (for Tartarate buffer) Potassium hydrogen phthalate (for Phthalate buffer) Potassium tetraoxalate dihydrate (for

Standard:IS 13428:2005
Gazetted SpecificationAnnexure E · clause 6.2
Official Gazette Text

Calcium hydroxide buffer) • Calcium Carbonate • Platinum dish, • Muffle furnace, • Hot Plate, • Fritted glass filter of medium PM/13428/3 January 2023 porosity, polyethylene bottle, PM/13428/3 January 2023 Suction pump & fritted glass funnel (for Tetra oxalate buffer) • Methyl orange, methyl red, bromothymol blue, phenolphthalein and alcohol (66%) (for universal indicator) • Thymol blue indicator (acid range) Bromophenol blue indicator • Bromocresol green indicator Methyl red indicator • Bromocresol purple indicator Bromothymol blue indicator Phenol Red indicator • Cresol Red indicator • Thymol Blue (alkali range) indicator • Thymolphthalein indicator • Thymol violet indicator • Different buffer solutions of known pH PM/13428/3 January 2023 B - CHEMICAL REQUIREMENTS SI. Tests Clause Ref. Referred Method of Test /Equipment /Apparatus* Chemical/Regents No. of IS Tests & 13428:2005 Limit of Detection (1) (2) (3) (4) (5) (6) 1. Nitrate (as 6.2, Sl. No. i) IS 3025 (Part 34) NO3) of Table 2 i) Cadmium Reduction • Reduction Column • Distilled water Method • Colorimeter OR • Nitrate free water • Spectrophotometer OR • Cadmium granules (40 – 60 mesh) Detection limit • Filter photometer Glass wool

Standard:IS 13428:2005
Gazetted SpecificationAnnexure E · clause 0.1
Official Gazette Text

• Hydrochloric Acid (6N) maximum 0.1 mg/l • 0.45 μm pore diameter membrane • Copper Sulphate Solution filter • Sulphanilamide Refrigerator • Conc. Hydrochloric Acid • N-(1-napthyl))-Ethylenediamine dihydrochloride (NED) Dihydrochloride) • Ammonium Chloride • Disodium Ethylene diamine tetra acetate • Ammonia Solution • Copper sulphate Solution – 2% Stock nitrate solution – 100μg/ml • (Potassium Nitrate & Chloroform) • Chloroform • Stock nitrite solution - 100μg/ml • (Potassium Nitrite & Chloroform) Nitrite free water ii) Chromotropic • Spectrophotometer • Nitrate free water Acid Method • Standard laboratory glasswares • Stock Nitrate Solution - 100μg/ml (Potassium Nitrate, Chloroform) • Standard Nitrate solution – 10.0μg/ml • Sulphite Urea Reagent (Urea & Anhydrous sodium Sulphite) PM/13428/3 January 2023 • Antimony reagent (Antimony metal, Conc. Sulphuric acid) • Chromotropic Acid Reagent (Purified chromotropic Acid crystals, Conc. Sulphuric Acid) Sulphuric Acid, Conc. Nitrate free iii) Devarda’s Alloy • Distillation Assembly (Kjeldahl • Ammonia Free Water Reduction Assembly) • Borate Buffer Solution (0.1N Sodium Method Hydroxide, 0.025M Sodium • Measuring Scoop spectrophotometer Tetraborate)

Standard:IS 13428:2005
Gazetted SpecificationAnnexure E · clause 0.02
Official Gazette Text

• Sodium Hydroxide – 6 N Detection limit • Devarda’s Alloy – 20 mesh with less minimum 2 mg/l than 0.005 percent Nitrogen • Mixed indicator Solution (Methyl Red indicator, Ethyl alcohol/Isopropyl alcohol, Methylene Blue) • Indicating Boric Acid Solution (Hydroboric Acid, mixed indicator solution) • Std. Sulphuric Acid Titrant - 0.02 N • Nessler’s Reagent (Mercuric Iodide, Potassium Iodine. Sodium Hydroxide) • Stock Ammonia Solution -1.22mg ammonia/ ml (Anhydrous Ammonium ammonia/ ml (Anhydrous Ammonium Chloride) • Standard Ammonia Solution 2 Nitrite 6.2, Sl. No. IS 3025(Part 34) • Spectrophotometer / Photometer • Nitrite Free water (Distilled water, ii) of Table 2 OR Hydroxide/Calcium Hydroxide Conc. • Nessler’s cylinders method Sulphuric Acid, Manganese Sulphate) • Nessler’s Tubes • Sulphanilamide Reagent • 0.45 μm Membrane Filter • NED Dihydrochloride Distillation Assembly (borosilicate) • Hydrochloric Acid • Sodium Oxalate – 0.05 N. • Ferrous Ammonium Sulphate – 0.05N (Ferrous Ammonium Sulphate, Conc. PM/13428/3 January 2023 Sulphuric Acid, Std. Dichromate solution) • Stock Nitrite Solution - 250μg of nitrogen/ml (Sodium Nitrite, Chloroform, Sodium Oxalate, Std., Potassium Permanganate solution)

Standard:IS 13428:2005
Gazetted SpecificationAnnexure E · clause 50.0
Official Gazette Text

• Intermediate Nitrite Solution – 50.0μg/ml Standard Nitrite Solution – 0.500μg/ml 3 Sulphide 6.2, Sl. No. IS 3025 (Part 29) • Glass Fibre Filter Paper. • Zinc acetate solution – 2N iii) of Table 2 • Reaction Flask (1 lit capacity with 2 • Sulphuric Acid, Conc. i) Iodometric Method hole stopper fitted with gas-diffusion • Standard Iodine solution – 0.025 N Detection limit tube. • (Potassium Iodide, Iodine) Hydrochloric • Absorption flasks (250ml Capacity) Acid, Conc. Standard Thiosulphate above 1 mg/l (2 No’s) Solution - 0.025 N (Sodium • Nitrogen/Carbon dioxide gas thiosulphate, Sodium cylinder Or Carbon dioxide gas Hydroxide/Chloroform) generator • Starch indicator solution (Starch, salicylic acid, toluene) • Aluminium Chloride solution – 6N • Sodium hydroxide – 6N ii) Methylene blue • Spectrophotometer (664 nm) or • N, N-dimethyl-p-Phenylene Diamine Method filterphotometer (600 nm). oxalate • Matched test tubes • Sulphuric Acid, Conc. & 1:1 solution Detection limit upto • Droppers • Ferric Chloride 20 mg/l • Dark glass bottle. • Diammonium Hydrogen Phosphate • Methylene Blue • Standard Sulphide Solution • Zinc acetate PM/13428/3 January 2023 4 Manganese 6.2, SI. No. i) IS 3025 (Part 59)

Standard:IS 13428:2005
Gazetted SpecificationAnnexure E · clause 1.75
Official Gazette Text

• Nessler’s Tubes • Sulphuric Acid iv) Table 2 • Beakers • Hydrogen Peroxide (30%) a) Periodate • Hot Plate • Nitric Acid, Conc. Colorimetric • Volumetric flask • Stabilized Distilled Water OR Method • Pipettes • Distillation Assembly, OR Detection limit up to • Conical Flasks • Distilled water, • Burette • Potassium Permanganate and 0.2mg/l • Dil Sulphuric Acid • Phosphoric Acid (sp. Gr. 1.75) • Potassium Periodate • Std. Manganese Solution ( 1ml=0.02 mg of Mn) (Standard 0.1 N Potassium Permanganate solution, saturated solution of sulphur dioxide) b) Formaldoxime • Fluoride Free Water • Potassium Peroxodisulphate or Sodium Spectrometric • Spectrophotometer Peroxodisulphate Method • Glass Bottle • EDTA Tetrasodium Salt, Solution, Autoclave c(EDTA) Detection limit • Sodium Hydroxide between 0.01mg/l to 5 • Hydroxyl ammonium Chloride mg/l • Formaldehyde • Ammonia Solution • Ammonium Iron (II) Sulphate Hexahydrate Solution • Sulphuric Acid, conc. Manganese Monohydrate (for Standard Mn Solution) PM/13428/3 January 2023 IS 3025 (Part 2) • Induction Coupled Plasma-Atomic • Nitric Acid Emission Spectrometer • Hydrogen Peroxide • Sample Bottles • Sulphuric Acid • Glasswares • Hydrochloric acid

Standard:IS 13428:2005
Gazetted SpecificationAnnexure E · clause 0.45
Official Gazette Text

• Acid Dispensers • Ammonium Sulfate • Membrane Filtration Equipment and • Stock Solution of Iron • A Filters (0.45μ) Hot Plate rgon gas 5 Copper IS 3025 (Part 2) • Induction Coupled Plasma-Atomic • Nitric Acid Emission Spectrometer • Hydrogen Peroxide • Sample Bottles • Sulphuric Acid • Glasswares • Hydrochloric acid • Acid Dispensers • Ammonium Sulfate • Membrane Filtration Equipment and • Stock Solution of Iron Filters (0.45μ) • Hot Plate 6.2, Sl No. Argon gas v) of Table 2 a) Neocuproine • Spectrophotometer & 1cm cell Hot • Ammonium Hydroxide Method • Chloroform, AR Grade plate Detection range 0.05 • Hydrochloric acid, Conc. • Separating funnels (125 ml) to 5.0mg/l • Hydroxylamine Hydrochloride • Conical flasks • Isopropyl Alcohol • Neocuproine • Double Distilled water • Nitric Acid, Conc. • Sulphuric Acid, Conc. • Hydrated Sodium Citrate • Stock copper (II) solution 200μg/ml (Pure Copper Metal, hot plate) • Hydrogen Peroxide PM/13428/ 3 January 2023 b) Atomic Abso- • Hydrochloric Acid, Conc rption Method • Nitric Acid, Conc. (Direct) • Dilute Sulphuric Acid Detection range 0.02 to • Atomic Absorption Spectro- photometer • Stock copper (II) solution – 1.0mg/ml 5.0mg/l with air-acetylene flame & Copper • (Pure Copper metal & hot plate)

Standard:IS 13428:2005
Gazetted SpecificationAnnexure E · clause 0.02
Official Gazette Text

Hollow Cathode lamp c) Atomic Absorption • Hydrochloric Acid, Conc. Method • Nitric Acid, Conc. (Chelation • Pyrrolidine Extraction) • Atomic Absorption Spectrophotometer • Dithiocarbamic acid Detection range 0.02 to with air-acetylene flame • Methyl Isobutyl Ketone, AR grade 5.0mg/l • Carbon Disulphide • Copper Hollow Cathode • Sodium Hydroxide Lamp Separating Funnel • Volumetric Flasks • Distilled water • Water Standard MIBK • Distillation Assembly • Bromophenol Blue • Ethanol or Isopropanol • Stock copper (II) solution – 1.0mg/ml • (Pure Copper metal & hot plate) d) Differential Pulse • Polarograph capable of • Hydrochloric Acid Conc. (Spectro Anodic Stripping Performing differential Grade) Voltametry pulse work • Nitric Acid-Conc. (Spectro Grade) Detection range 0.01 • Hanging Mercury Drop • Sulphuric Acid Conc. to electrode • Pure Copper Metal 0.1mg/l • Platinum Counter • Granular Zinc Electrode • Mercury • Saturated Calomel Reference Electrode • Magnetic Stirrer • Control unit with Stirring Bar • Scrubber Assembly • Whatman Filter Paper PM/13428/ 3 January 2023 No. 40 PM/ 13428/ 3 January 2023 • Nitrogen Gas i) IS 3025 • Induction Coupled Plasma-Atomic • Nitric Acid Emission Spectrometer • Hydrogen Peroxide

Standard:IS 13428:2005
Gazetted SpecificationAnnexure E · clause 0.45
Official Gazette Text

(Part 2) • Sample Bottles • Sulphuric Acid • Glasswares • Hydrochloric acid • Acid Dispensers • Ammonium Sulfate • Membrane Filtration Equipment and • Stock Solution of Copper Filters (0.45μ) • Hot Plate • Argon Gas 6. Flouride 6.2, Sl. No. IS 3025(Part 60) vii) of Table i) Zirconium • Nessler Tubes (100ml)Distillation • Thiosulphate Solution (0.1 N) 2 alizarin Apparatus • Standard Sodium Fluoride Solution • Refrigerator (Recommended) (1ml = 0.01 mg F) Method Heating mantle • Zirconium Oxychloride OR Zirconium Oxynitrate Detection range • Alizarin Sodium Monosulphonate 0.05 to 1.0 mg/l (AlizarinS) • Conc. Hydrochloric Acid • Conc. Sulphuric Acid • Silver Sulphate • Perchloric Acid • Phenolphthalein Indicator • Sodium Hydroxide Solution ii) Electro Chemical • Millivolt Meter • Sodium Hydroxide- 5 M Probe Method • Fluoride Ion – Selective Electrode • Total Ionic Strength Adjustment Buffer Detection range • Reference Electrode – Either a (TISAB)-[Sodium Chloride, Glacial calomel electrode, Acetic Acid, Sodium Hydroxide, 0.2mg to 2.0 g/l filled with saturated Potassium CDTA( trans -1,2- diaminocyclohexane Chloride (KCl) Solution or a Silver / – N,N,N’,N’ tetra acetic acid)] Silver Chloride Electrode

Standard:IS 13428:2005
Gazetted SpecificationAnnexure E · clause 6.2
Official Gazette Text

• Measuring Cells – • Fluoride, Stock Solution, 1000mg/1 100ml(Polypropylene fitted with (Sodium Fluoride ) thermostated jacket) • Water Bath • Magnetic Stirrer with a polytetrafluoroethylene(PTFE) PM/ 13428/ 3 January 2023 • Polyethylene Beaker • pH meter • Standard Volumetric • Glasswares • Desiccator • Screw Capped Polyethylene Container • Plastic Bottle Note : • Purity of the reagent – Unless specified otherwise, only pure chemicals & Fluoride free distilled water shall be used in tests. 7. Barium 6.2, Sl. No i) of Table 2 i) Annex G of IS 13428 Filter paper and filtration assembly Hot plate/gas burner • Ammonium Dichromate • Ammonium Acetate • Ammonium Hydroxide • Potassium Iodide • Sodium Thiosulphate(0.1N) • Hydrochloric Acid • Ammonium Chloride Starch indicator ii) IS 15302 • Atomic Absorption Spectrophotometer and • Associated equipment (Burner, Readout mechanism, lamp for Barium, Pressure Reducing valves and vents) • Nitrous oxide burner head • T-junction valve or other switching valve • Air • Acetylene Gas Nitrous oxide gas • Metal free water • Hydrochloric Acid • Nitric Acid • Sulphuric Acid • Hydroflouric Acid • Potassium Chloride • Standard barium solution 100μg/ml (Barium chloride, oven, hydrochloric

Standard:IS 13428:2005
Gazetted SpecificationAnnexure E · clause 0.45
Official Gazette Text

acid) iii) IS 3025 (P 2) • Induction Coupled Plasma-Atomic Emission • Spectrometer • Sample Bottles • Glasswares • Acid Dispensers • Nitric Acid • Hydrogen Peroxide • Sulphuric Acid • Hydrochloric acid • Ammonium Sulfate Stock Solution of Barium PM/ 13428/ 3 January 2023 • Membrane Filtration Equipment and Filters (0.45μ) • Hot Plate Argon Gas 8. Antimony 6.2 Sl. No. i) Annex H of IS 13428 • Spectrophotometer (565 nm) • Hydrochloric Acid – 6 N ix) of Table 2 • Erlenmeyer Flask (125ml) • Phosphoric Acid – 3N Spectrophoto-metric • Separating Funnels (125 ml) with • Rhodamine B Method Teflon • Antimony Standard • Stopcocks • Solution (100 μg/ml and 1 ug/ml (pure • Refrigerator antimony, sulphuric acid) • Ice Bath • Benzene • Test Tubes • Sulphuric Acid • Perchloric Acid Pipettes ii) IS 15303 • Atomic Absorption Spectrometer • Metal free Water with • Hydrochloric Acid, Conc. Electrothermal Atomic • Nitric Acid, Conc. Absorption • Hollow Cathode Lamp OR • Matrix Modifier Stock Solutions Spectrometric Method • Electrodeless discharge lamp (EDL). (Magnesium Nitrate, Nickel Nitrate, • Graphic Furnace Phosophoric Acid, Palladium Nitrate, • Readout Mechanism Citric Acid) • Microlitre Pipettes-5 to 100 μl. OR

Standard:IS 13428:2005
Gazetted SpecificationAnnexure E · clause 1.00
Official Gazette Text

• Stock Metal Solution • Antimony Solutions (100 μg/m Sb) • Automatic sampling device designed • Iron-100μg Fe for the specific instrument. • Selenam-1.00 mg Sb • Vent for Fumes • Chelating Resin • Cooling Device Sodium hydroxide -10 N Membrance Filter Apparatus (0.45μm) or smaller pore diameter membrane filters. 9. Borate 6.2, Sl. No.

Standard:IS 13428:2005
Gazetted SpecificationAnnex J of IS13428 · clause 5.9
Official Gazette Text

• Spectrometer (410 – 420nm) • Azomethine – H, Sodium Salt x) of Table 2 • Lab Apparatus made of • L - Ascorbic Acid Polypropylene/Polyethylene/Polytetra • Buffer Solution (pH 5.9) [Ammonium fluoro Ethylene Acetate, Sulphuric Acid, Phosphoric Refrigerator Acid, Citric Acid, Disodium Ethylene diamine – Tetraacetic Acid Dihydrate] • Borate Stock Solution - (1mg/ml) (Boric Acid) PM/ 13428/ 3 January 2023 • Boron Standard Solution - 10μg/ml Calcium Hydroxide 10. Silver 6.2, Sl. No.

Standard:IS 13428:2005
Gazetted SpecificationAnnex K of IS 13428 · clause 6.2
Official Gazette Text

• Atomic Absorption Spectrophotometer • Deionised Distilled Water (Ion xi) of Table 2 with Oxidizing Air Acetylene Flame Exchange Column & Distilled Water) • Nitric Acid – Redistilled • Hydrochloric Acid – Redistilled • Silver Std. Solution (Silver Nitrate) • Lanthanum Chloride • Lanthanum Stock Solution (Lanthanum Oxide, Hydrochloric Acid) • Ammonium Pyrrolidine Dithiocarbamate solution) • Methyl isobutyl ketone 11. Chloride 6.2, Sl. No IS 3025 (Part 32) • Erlenmeyer Flask (250ml) • Potassium Chromate Indicator Solution .xii) of Table (Potassium Chromate, Silver Nitrate) 2 i) Argentometric Burette • Standard Silver Nitrate Solution – 0.01 N (silver nitrate, sodium Method chloride) • Standard Sodium Chloride Solution – 0.01 N (Sodium Chloride) • Aluminium Hydroxide Suspension (Aluminium Potassium Sulphate or Aluminium Ammonium Sulphate, Conc Ammonium Hydroxide) • Phenolphthalein Indicator Solution • Sodium Hydroxide – 1N • Sulphuric Acid – 1N Hydrogen Peroxide – 30% ii) Mercuric Nitrate • Erlenmeyer Flask (250 ml) • Standard Sodium Chloride Method • Microburette (5 ml with l.c. 0.01ml) Solution, 0.01N • Refrigerator • Nitric Acid, 0.1N • pH meter • Sodium Hydroxide, 0.1N PM/ 13428/ 3

Standard:IS 13428:2005
Gazetted SpecificationAnnex K of IS 13428 · clause 6.2
Official Gazette Text

January 2023 • Indicator – Acidifier Reagent (S- Diphenyl- carbazone, Conc. Nitric Acid, Xylene Cyanol FF, Ethyl Alcohol or Isopropyl Alcohol) • Standard Mercuric Nitrate Solution, 0.01N (Mercuric Nitrate, Conc. Nitric Acid, Sodium Bicarbonate, Std. Sodium Chloride Solution) • Mixed Indicator Reagent (Diphenylcarbazone, Bromo Phenol Blue, Ethyl Alcohol or Isopropyl Alcohol) • Standard Mercuric Nitrate Solution – 0.1N iii) Potentiometric • Glass and Silver- Silver Chloride • Standard Sodium Chloride Solution Method Electrodes (0.01N) • Nitric Acid-Conc • Electronic Voltmeter • Standard Silver Nitrate Solution (0.01N) • Pretreatment Reagent (Sulphuric Acid, • Mechanical Stirrer Hydrogen Peroxide, Sodium Hydroxide • –1N) • PM/ 13428/ 3 January 2023 iv) Automated • Automated Analytical Equipment • Stock Mercuric Thiocyanate Solution Ferricyanide Method (Mercuric Thiocynate, Methanol) Filters (480nm) • Stock Ferric Nitrate Solution (Ferric Nitrate, Conc. Nitric Acid) • Colour Reagent (Poly oxy Ethylene 23 Lauryl Ether) Sodium Chloride 12 Sulphate 6.2, Sl. No. IS 3025 (Part 24) xiii) of Table 2 • Steam Bath • Methyl Red Indicator i)Gravimetric Method • Drying Oven (thermostatically • Hydrochloric Acid

Standard:IS 13428:2005
Gazetted SpecificationAnnex K of IS 13428 · clause 0.45
Official Gazette Text

controlled) • Barium Chloride Detection limit more • Muffle Furnace • Silver Nitrate than 10mg/l • Desiccator • Nitric Acid • Analytical Balance (l.c.0.1mg) • Ion Exchange Resin (Amberlite IR-120 • Filter Paper (Preferably Whatman or Equivalent) No.42) • Silica or Porcelain Crucible (max pore size of 5 microns) • Ion Exchange Column • Filter (0.45 μ m) • Platinum Dish ii) Thorin Method • White Porcelain Basin • Ethyl Alcohol • Burette • Ammonium Hydroxide (Ammonia-Conc Detection range 5 to • Ion Exchange Column and Distilled Water) 150mg/l • Filter – 0.45μm • Hydrochloric Acid • Thorin (2,2 – Hydroxy – 3,6 – Disulpho – 1 – Naphthylazo Benzene Arsenic Acid) • Ion Exchange Resin (Amberlite IR-120 or Equivalent) • Stock Sulphate Solution – 100 mg/l • (Anhydrous Sodium Sulphate) PM/ 13428/ 3 January 2023 iii) Turbidity • Turbidity Meter or • Barium Chloride – Standard Solution Method Spectrophotometer`(420nm) (Barium chloride in hydrochloric acid • Glass Apparatus ammonia) Detection limit 1 to • Hot Plate • Barium Chloride 40mg/l • Refrigerator (recommended) • Gelatin Powder Filter – 0.45μm • Glycerol • Hydrochloric Acid, Conc • Sodium Chloride • Ethyl or Isopropyl Alcohol • Anhydrous Sodium Sulphate

Standard:IS 13428:2005
Gazetted SpecificationAnnex K of IS 13428 · clause 6.2
Official Gazette Text

• Stock sulphate solution – 100mg/l 13. Magnesium 6.2, Sl No. i) IS 3025 (Part 46) • Vacuum Pump • Methyl Red Indicator xiv) of Table • Filter Flasks • Hydrochloric Acid 2 a)Gravimetric Method • Filter Crucibles (medium porosity, • Ammonium Oxalate 30 ml) • Ammonium Hydroxide Detection limit more • Nitric Acid, Conc • Muffle Furnace than 1 mg/l • Diammonium Hydrogen Phosphate • Hot plate • Urea • Volumetric Flasks • Glasswares b)Volumetric Method • Hot plate • Indicator Solutions (EDTA) • Volumetric Flasks i)Patton and Reeder Reagent, • Glasswares Sodium Chloride/Potassium • Chloride ii) Murexide (Ammonium Purpurate), Absolute Ethylene Glycol, Sodium Chloride iii) Eriochrome Black T Indicator (EBT Indicator), Hydroxylamine, Hydrochloride, Ethanol/Methanol • Standard Zinc Solution – 0.01M (Pure Zinc Dust/Granules – 99.9% Pure; Hydrochloric Acid) • Buffer Solution (Ammonium Chloride, Ammonia, Sodium Hydroxide-1N) PM/ 13428/ 3 January 2023 • Standard Ethylene Diamine Tetra Acetic Acid (EDTA) Solution – 0.001M (Disodium Ethylene Diamine Tetra Acetate Dihydrate, Standard Zinc Solution) • Triethanolamine Solution – 10% Potassium Cyanide • Hydroxlamine Hydrochloride c) Atomic Absorption • Atomic Absorption • Hydrochloric Acid – 1N and 0.1N

Standard:IS 13428:2005
Gazetted SpecificationAnnex K of IS 13428 · clause 0.03
Official Gazette Text

Method Spectrophotometer ( 285.2 nm ) with • Lanthanum Chloride (Lathanum Air-Acetylene Flame or Nitrous Oxide, Hydrochloric Acid, Conc) Detection limit max 5 Oxide-Acetylene Flame and Hollow • Cesium Chloride mg/l Cathode Lamp (Magnesium) Standard Magnesium Solution (1000mg/l) • Polyethylene Bottles (Magnesium Oxide, Hydrochloric Acid) i) IS 3025(Part 2) ICP AES (279.079nm) including - • Nitric Acid computer controlled aes with • Hydrogen Peroxide Inductively Coupled background correction radio frequency • Sulphuric Acid Plasma Atomic generator argon gas supply ( welding • Hydrochloric Acid Emission Spectroscopy grade or better) • Ammonium Sulphate • Distilled Water Detection limit • Sample bottles • Magnesium Stock solution ( 10 mg/l ) 0.03 mg/l • Glassware ( beakers, filter funnels, • volumetric flasks, pipettes) acid dispensers • Membrane filtration equipment 14 Calcium 6.2 Sl. No. i) IS 3025 (Part 40) • Sodium Hydroxide Solution – 1N xv) of Table • Hydrochloric Acid – 0.1N 2 • Indicator Solution:Murexide a)EDTA Titrimetric (Ammonium Purpurate) Indicator, Method • Hot Plate Absolute Ethylene Glycol • Glassware • Sodium Chloride • Polyethylene Bottle OR • Patton and Reeder’s Indicator

Standard:IS 13428:2005
Gazetted SpecificationAnnex K of IS 13428
Official Gazette Text

(Eriochrome Blue Black R, Sodium Sulphate/Potassium Sulphate) PM/ 13428/ 3 January 2023 • Standard EDTA Solution – 0.01M (Disodium Ethylene Diamine Tetra – Acetate, Standard Zinc Solution, (Or Standard Calcium Solution) Buffer Solution, Eriochrome Black T Indicator Solution • Stock Calcium Solution (Calcium Carbonate, Hydrochloric Acid – 0.1N) • Nitric Acid, Conc • b)Atomic Absorption • Atomic Absorption Spectrometer • Hydrochloric Acid – 1N and 0.1N Spectrometric Method (422.7 nm ) with Air/Acetylene or • Lanthanum Chloride Detection limit Nitrous Oxide/Acetylene Flame and • Cesium Chloride Hollow Cathode Lamp (Calcium) • Standard Calcium Solution maximum 50mg/l c) Permanganate • Beakers, Cover Glass, and Glass • Hydrochloric Acid – 1N Titration Method Rod Filtration Set up (Gooch • Methyl Red Indicator Solution Crucible with Suction) • Ammonium Oxalate Solution Hot plate • Urea • Dilute Sulphuric Acid – 1N • Sodium Oxalate • Standard Potassium • Permanganate Solution (Potassium permanganate, sodium oxalate) ii) IS 3025(Part 2) • ICP AES ( 315.887 nm) including • Nitric Acid Inductively Coupled – • Hydrogen Peroxide Plasma Atomic • computer controlled a e s with • Sulphuric Acid Emission Spectroscopy background correction • Hydrochloric Acid

Standard:IS 13428:2005
Gazetted SpecificationAnnex K of IS 13428 · clause 0.1
Official Gazette Text

(a e s) • radio frequency generator • Ammonium Sulphate Detection limit • argon gas supply ( welding grade • Distilled Water Calcium Stock solution ( 10 mg/l) 0.1 mg/l or better) • Sample bottles • Glassware ( beakers, filter funnels, volumetric flasks, pipettes) • acid dispensers PM/ 13428/ 3 January 2023 • Membrane filtration equipment • Filter of pore size 0.45 microns 15. Sodium 6.2, Sl No. xvi) of Table 2 i) IS 3025 (Part 45) a) Flame Emission Photometric Method anyone of the following applicable detection range:(0 to 1)mg/lit(1 to 10)mg/lit (0 to 100)mg/lit • Flame Photometer (Direct Reading OR Internal Standard Type) OR Atomic Absorption Spectrophotometer (In Flame Emission Mode) • Deionized Distilled Water • Stock Sodium Solution – 1mg/ml (Sodium Chloride) • Standard Lithium Solution – 1mg/ml b)Atomic Absorption • Atomic Absorption Spectrophotometer with Air- Acetylene Flame and Hollow Cathode Lamp (Sodium) • Glassware • Beakers (20ml, Borosilicate) • • Sodium Chloride Spectrometry Method • Potassium Chloride Detection range 0.20 to 4.0mg/l • Stock Sodium Solution – 1mg/ml • Stock Potassium Solution – 1mg/ml c)Gravimetric Method • Fritted Glass Crucible or Porous • Zinc Uranyl Acetate Reagent (Glacial

Standard:IS 13428:2005
Gazetted SpecificationAnnex K of IS 13428 · clause 0.45
Official Gazette Text

Porcelain Crucibles • Vacuum Pump or Aspirator • Filter paper • Pyrex bottle Stirring rod Conc. Acetic Acid, Uranyl Acetate Dihydrate, Zinc Acetate Dihydrate, Sodium Chloride) Ethyl Alcohol Wash Solution (Ethyl Alcohol, Pure Sodium Zinc Uranyl Acetate, Sodium Chloride, Acetic Acid, Diethyl Ether) ii) IS 3025(Part 2) • Oven • Membrane filtration equipment and filters(0.45μm) • Inductively coupled plasma atomic emission spectrometer; Computer controlled AAS with background correction, Radiofrequency Generator, Argon Gas supply(welding grade or better) • Nitric acid • Hydrogen peroxide • Sulphuric acid • Ammonium sulphate • Sodium Stock solution • • pH meter PM/ 13428/ 3 January 2023 • PTFE container • PTFE sample bottles(250 ml or 500ml) • Acid dispensers, Variables • 16. Alkalinity 6.2, Sl. No. IS 3025 (Part 23) Distilled Water xvii) of Table • pH Meter • Sulphuric Acid, Conc 2 • Burette • Sulphuric Acid, 0.02 N i) Indicator Method • Magnetic Stirrer Assembly • Phenolphthalein Indicator • Beaker • Mixed Indicator Solution (Methyl Red, Detection • Bromocresol Green, Ethyl or Isoprophyl range 0. 5 to Alcohol) 500mg/l ii)Potentiometric • Potentiometer Standard Sulphuric Acid – 0.02N Method

Standard:IS 13428:2005
Gazetted SpecificationAnnex K of IS 13428 · clause 0.5
Official Gazette Text

Glasswares Detection range 0.5 to 500mg/l 17. Selenium 6.2, Sl. No. i) IS 3025 (Part 56) xviii) of a)Spectrophotometric Table 2 Method • Spectrophotometer (480nm,light path • Stock Selenium Solution – 1.0mg/ml of 1cm (Sodium Selenite, Hydrochloric Acid) (Diamino naphthalene • Volumetric Glasswares • Hydrochloric Acid – 0.1N Method) • Separating Funnel (250ml) Preferably • Ammonium Hydroxide,1:1Cyclohexane • Flourocarbon Stopcock • 2,3 – Diaminonaphthalene (DAN) Detection limit • Water Bath – Thermostatically • Hydroxylamine Hydrochloride minimum 0.01mg/l Controlled • Sodium Salt of EDTA • pH Meter • Amberlite XAD -8 or Equivalent Resin • Centrifuge • Hydrochloric Acid, Conc Centrifuge Bottles with Flourocarbon Potassium Hydroxide Screw Cap b) Atomic absorption • Atomic Absorption Spectrometer • Nitric Acid Spectrometric Method (196.0 nm) Fitted with Hydride • Sulphuric Acid (Hydride Technique) System and Hollow Cathode • Hydrochloric Acid Lamp/Electrodeless Discharge Lamp • Hydrogen Peroxide • Gas (Argon or Nitrogen) • Sodium Hydroxide • Sodium Tetrahydro borate PM/13428/ 3 January 2023 • Glasswares Decomposition Apparatus • Selenium Stock Solution (1mg/ml) (Round Bottom Flask, Reflux (Selenium Dioxide)

Standard:IS 13428:2005
Gazetted SpecificationAnnex K of IS 13428 · clause 6.2
Official Gazette Text

Condenser, Condensate Reservoir) 18 Mineral Oil 6.2, Sl No. Clause 6 of IS 3025 • Separating Funnel (1lit) with Teflon • Hydrochloric Acid xix) of Table (Part 39) or Equivalent Stopcock • Hexane 2 • Infra-Red Spectrophotometer – • Sodium Sulphate, Anhydrous Partition Infra-Red Double Beam, Recording type • Reference Oil (Iso-Octane, Hexadecane, Method • Cells – Infra-Red, Silica Benzene) Detection limit 0.5 to • Filter Paper – Whatman No.40 or • Trichlorotrifluoroethane Equivalent, 11cm Diameter 100 mg/l Analytical Balance 11 19 Phenolic compounds (as C 6 H 5 OH) 55.3, Sl No. xix) of Table 2 Clause 6 of IS 3025 (Part 43)  Spectrophotometer  pH Meter  Phenol Standard Solution  Glass distilling apparatus with Graham condenser  Water bath  Buchner funnels with fritted discs  Filter Paper – Whatman No.40 or equivalent  1000 ml capacity separating funnel with ground glass stoppered and TFE stop cock  Ferrous Sulphate  Phosphoric Acid  Sodium Hydroxide pellets  Chloroform  Sodium Sulphate  Ammonium Hydroxide  Phosphate Buffer solution  4-Aminoantipyrine solution  Potassium Ferricyanide solution  Phosphoric Acid 20 Anionic 6.2, Sl No. Annex L of IS 13428 • pH Meter • Sodium Chloride

Standard:IS 13428:2005
Gazetted SpecificationAnnex K of IS 13428 · clause 0.05
Official Gazette Text

Surface xx) of Table • Spectrophotometer (650 nm) 10mm • Ethyl Acetate Active 2 Detection limit about & 50mm cells • Al2O3 Agents (as 0.05 mg/l • Chloroform MBAS) • Gas Stripping Apparatus (1 lit • Ethanol Capacity) • Methanol • Nitrogen Air (20 ltr/hr to 50 ltr/hr) • Sulphuric Acid • Reflux Condenser • Ethanolic Sodium Hydroxide-0.1 mol/lit • Fuming hood (Sodium Hydroxide, Ethanol) • Water bath • Methylene Blue, Neutral Solution • Methylene Blue, Acidic Solution • Buffer Solution, pH 10 (Sodium PM/13428/ 3 January 2023 Hydrogen Carbonate, Anhydrous Sodium Carbonate) • Phenolphthalein Indicator, Ethanol Dodecyl Benzene Sulphonic Acid Methyl Ester (Tetrapropylene Type), Stock Standard Solution PM/13428/ 3 January 2023 C- REQUIREMENTS FOR TOXIC SUBSTANCES SI. Tests Clause Ref. of Referred Method of Test /Equipment /Apparatus Chemical/Regents No. IS 13428:2005 Tests & Limit of Detection (1) (2) (3) (4) (5) (6) 1 MERCURY 6.2, Sl. No.v) of IS 3025 (Part 48) • Atomic Absorption Spectrometer and • Sulphuric acid, conc. Table 3 i) Cold Vapour Associated Equipment (Cold Vapour • Nitric acid, Conc. Atomic Absorption Technique) • Stannous chloride Spectrophotometry • Mercury Vapour Generation • Hydrochloric acid, Conc.

Standard:IS 13428:2005
Gazetted SpecificationAnnex K of IS 13428 · clause 0.25
Official Gazette Text

Detection limit Assembly • Sodium chloride • Mercury Hollow Cathode Lamp • Hydroxylamine sulphate 0.0002 mg/l, Min • Recorder/Printer/Display • Potassium permanganate Meter • Potassium persulphate • BOD bottle, 300 ml • Mercuric chloride • Water bath • Mercury free distilled • Equipment assembly as per Fig 1 water ii) Colorimetric • Spectrophotometer • Redistilled or Deionised Dithizone Method • Separating Funnels (250 and 1000ml Distilled Water (Mercury with PTFE stopcocks) free) Detection limit • Glass wares • Mercuric chloride 0.002 mg/l, Min • Whatman Filter No. 42 • Nitric acid, Conc. • Potassium permanganate • Potassium persulphate • Hydroxylamine hydrochloride • Dithiozone solution, 6 μg/ml • Sulphuric acid – 0.25 N • Potassium bromide • Chloroform • Disodium hydrogen phosphate • Anhydrous potassium carbonate • Sodium sulphate, Anhydrous PM/13428/ 3 January 2023 • Hydrochloric acid(1:1) • Ammonium hydroxide 2 CADMIUM 6.2, Sl. No. ii) IS 3025 (Part 41) • Atomic Absorption spectrophotometer • Hydrochloric acid, Conc. of Table 3 with Air-Acetylene Flame • Nitric acid, Conc. i) Atomic • Nitric acid, dilute – 1:499 Absorption • Cadmium Hollow Cathode Lamp or • Pure Cadmium Metal Method (Direct)

Standard:IS 13428:2005
Gazetted SpecificationAnnex K of IS 13428 · clause 0.05
Official Gazette Text

Multi Element Hollow Cathode Lamp Detection range for Use at 228.8 nm 0.05 to 2mg/l ii) Atomic • Atomic Absorption spectrophotometer • Hydrochloric acid, Conc. Absorption Method with Air-Acetylene Flame • Hydrochloric acid – 1:49 (Chelation and • Nitric acid, Conc. Extraction) • Cadmium Hollow Cathode Lamp or • Nitric acid, dilute – 1:499 Detection range • Multi Element Hollow Cathode Lamp • Pure Cadmium Metal for use at 228.8 nm • Sodium hydroxide 0.005 to 0.2mg/l • Separating funnel • Methyl Isobutyl Ketone (MIBK) • pH meter • Bromophenol Blue • pH paper • Ethanol or Isopropanol • Pyrrolidine dithiocarbamic acid • Carbon Disulphide iii) Differential Pulse • Polarograph – Capable of Differential • Hydrochloric Acid, Conc., Anodic Stripping Pulse Work spectrograde Voltametry • Hanging Mercury Drop Electrode • Nitric Acid, Conc., Detection range • Platinum Counter Electrode spectrograde 0.0001 to 0.1mg/l • Saturated calomel Reference Electrode • Nitric Acid, dil – 1:1 • Magnetic Stirrer Control Unit with • Hydroxylamine Hydrochloride Stirring Bar • L-Ascorbic Acid • Nitrogen Gas (Cylinder) • Pure Cadmium Metal • Scrubber assembly for nitrogen • Granular Zinc purification • Mercury •

Standard:IS 13428:2005
Gazetted SpecificationAnnex K of IS 13428 · clause 6.2
Official Gazette Text

Voltametric Cell assembly • Ammonium Meta Vanadate PM/13428/ 3 January 2023 3 ARSENIC 6.2, Sl. No. i) IS 3025(Part 37) of Table 3 i) Atomic absorption • Atomic absorption spectrometer • Argon or Nitrogen and method equipped with gas flow meter for Hydrogen Argon or Nitrogen and Hydrogen and • Sodium borohydride Detection limit with arsenic electrodeless discharge • Sodium hydroxide 0.001 mg/l lamp • Sodium Iodide • Atomizer • Sulphuric acid-18N & 2.5 N • Reaction cell for producing arsenic • Potassium persulphate hydride • Eye dropper or syringe • Nitric acid, conc • Refrigerator • Perchloric acid, conc • Hydrochloric acid, conc • Arsenic trioxide • Arsenic pentaoxide • Dimethyl arsenic acid/cacodylic acid • Calcium chloride ii) Silver diethyl Arsine generator & absorption assembly • Hydrochoric acid , Conc dithiocarbamate (Fig. 2 of IS 3025 Pt 37) • Potassium Iodide method Spectrophotometer, 535 nm with 1 cm • Stannous chloride, arsenic free (Referee method) cells • Lead acetate Detection limit • Ephedrine 0.001 mg/l • Pyridine • Chloroform • Silver diethyl dithiocarbamate • Zinc – 20 to 30 mesh, arsenic free • Arsenic trioxide • Sodium hydroxide iii) Mercuric Arsine generator glass assembly (Fig 3 of • Sulphuric acid (1:1)

Standard:IS 13428:2005
Gazetted SpecificationAnnex K of IS 13428 · clause 6.2
Official Gazette Text

bromide stain IS 3025 Pt 37) • Nitric acid, conc method • Roll cotton PM/13428/ 3 January 2023 • Lead acetate • Arsenic papers • Mercuric bromide • Ethyl alcohol/isopropanol • Potassium iodide • Arsenic free stannous chloride • Zinc-20 to 30 Mesh, arsenic free • Arsenic trioxide • Sodium hydroxide 4 CYANIDE 6.2, Sl. No. iii) IS 3025(Part.27) of Table 3 i) Total cyanide after • Distillation apparatus consisting of • Sodium hydroxide distillation method boiling flask, 1l, thistle tube, Allihn • Lead carbonate-powdered water cooled condenser, gas • Sulphamic acid dispersion tube, needle valve, suction • Magnesium chloride Detection limit flask and suction pump (Fig 1 of IS • Sulphuric acid, conc minimum 0.02 mg/l 3025 Pt 27) • Heating mantle • Acetic acid, glacial • Gas absorber • Potassium cyanide • Ground glass ST joints • Silver nitrate • Spectrophotometer for use at 62 nm • Chloramine – T with 1-cm cell • Pyridine • pH paper • Pyrazolone • Thermometer – 0 o C – 110 0 C, l.c. 1 o C • BIS – pyrazolone ii) Selective • Expanded – scale pH meter or specific • Potassium cyanide electrode method Ion meter • Silver nitrate • Cyanide Ion selective electrode • Sodium hydroxide Detection range • Reference electrode, double junction

Standard:IS 13428:2005
Gazetted SpecificationAnnex K of IS 13428 · clause 0.05
Official Gazette Text

• Potassium nitrate 0.05 to 10 mg/l • Potassium hydroxide PM/13428/ 3 January 2023 • Magnetic mixer with TFE coated stirring Bar 5 LEAD 6.2, Sl. No. vi) IS 3025(Part 47) of Table 3 • Hydrochloric acid, conc i) Atomic absorption • Atomic absorption spectrophotometer • Nitric acid, conc. method (direct) with air acetylene flame • (Lead nitrate Detection range 1.0 • Hollow cathode lamp OR • Nitric acid, dil (1:499) to 10.0mg/l Electrodeless Discharge lamp for use at 283.3 nm • Hydrochloric acid, conc ii) Atomic absorption • Hydrochloric acid, dil (1:2) method (chelation – • Atomic absorption spectrophotometer • Hydrochloric acid, dil (1:49) extraction) with air acetylene flame • Nitric acid, conc. • Hollow cathode lamp OR Electrode • Pyrrolidine less Discharge lamp for use at 283.3 • Chloroform nm • Separatory funnel • Carbon disulphide • 0.45μm membrane filter • Sodium hydroxide • Acid washed filter paper. • Bromophenol blue • pH meter • Lead nitrate iii) Differential pulse Polarograph capable of performing anodic stripping differential pulse work voltametry (DPASV) • Hanging mercury drop electrode • Lead nitrate • Platinum counter electrode • Hydrochloric acid, conc. Detection range • Saturated calomel reference electrode • Nitric acid, conc.

Standard:IS 13428:2005
Gazetted SpecificationAnnex K of IS 13428 · clause 0.45
Official Gazette Text

0.001 to 0.1mg/l • Magnetic stirrer control unit with • Nitric acid, dil (1:1) stirring bar • Granular zinc • Scrubber assembly for nitrogen • Mercury purification • Ammonium metavanadate • Nitrogen gas (cylinder) • 0.45μm membrane filter iv) Dithizone method • Spectrophotometer for use at 510 nm • Lead free distilled water Detection limit with 1-cm cell • Lead nitrate 0.1 mg/l • pH meter • Nitric acid, 95% (w/w) • TEF beakers, 100 ml • Nitric acid, dil 20% (w/w) • Separating funnels, 250 ml, 500 ml • Nitric acid, dil (1:1) • Ammonium hydroxide Conc. (14 N) PM/13428/ 3 January 2023 • Ammonium hydroxide, dil. 10% ( v/v) • Ammonium hydroxide, dil. 1% v/v) • Anhydrous Ammonium Citrate • Anhydrous Sodium Sulphite • Hydroxylamine hydrochloride • Potassium cyanide • Dithizone • Chloroform • Hydrochloric acid (1:1) 6 CHROMIUM 6.2, Sl. No. vi) Annex K of IS • Atomic absorption spectrophotometer • Deionised distilled water, of Table 3 13428 with reducing Air – acetylene flame Ammonia free • 0.45μm membrane filter • Nitric acid, redistilled – 1:1 • pH meter (v/v) • Centrifuge • Hydrochloric acid, redistilled – 1:1 (v/v) • Chromium oxide • Lanthanum chloride • Lanthanum oxide , 99.9%, w/w • Ammonium pyrrolidine

Standard:IS 13428:2005
Gazetted SpecificationAnnex K of IS 13428 · clause 6.2
Official Gazette Text

dithiocarbamate 7 NICKEL 6.2, Sl. No. vii) Annex M of IS • Atomic absorption spectrophotometer • Nitric acid, conc. – 1.4 g/ml of Table 3 13428 with nebulizer – burner having air- • Pure nickel metal acetylene flame • Sodium hydroxide • Centrifuge • Hydrochloric acid, conc. – • Nickel hollow cathode lamp/electrode 1.19 g/ml less discharge lamp • Methyl isobutyleketone • Separating funnel, 250-ml with PTFE (MIBK) taps • Ammonium 1 – pyrrolidino • pH meter carbodithioate • Bromophenol blue • Ethanol PM/13428/ 3 January 2023 8 POLY 6.2, Sl. No. Annex N of IS • Gas chromatograph with EC detector • Silica gel, 60 – 100 mesh CHLORINATED viii) of Table 3 13428 & coupled with printer-plotter-cum- • N-hexane-redistilled BIPHENYLE integrator • Potassium hydroxide pellets (PCB) • Glass chromatographic column, 300 • Sodium hydroxide solution – mm long, 8 mm ID with ground glass 5N socket at the upper end and a stop • Diethyl ether, cock at low end. chromatography grade • Kuderna-Danish type, evaporator • Cotton wool, extracted with • Snyder columns hexane and diethyl ether • Syringe (5 μl) • Acetic acid, glacial, • Heating oven redistilled • Desiccator • Chromium trioxide, re- crystallized • Apiezon L grease

Standard:IS 13428:2005
Gazetted SpecificationAnnex K of IS 13428 · clause 0.15
Official Gazette Text

• Epikote Resin 1001 – 0.15 % • Chromosorb G (acid washed) DMCS treated, 60 – 80 mesh • Silicone gum GE-S-SI – 1.3 % 9 POLYNUCLEAR 6.2, Sl. No. ix) i) High Performance • High Performance Liquid • Reagent Water AROMATIC of Table 3 Liquid Chromatograph (HPLC) complete with • Sodium thiosulphate, granular HYDROCARBON APHA 6440 Chromatography gradient pumping system, reverse • Cyclohexane (HPLC) Method phase column and detectors (UV and • Methanol fluorescence) • Acetone, ii) Gas • Gas Chromatograph (GC) complete • Methylene chloride chromatographic with column and flame ionization • Pentane – Pesticide quality or (GC) Method detector. equivalent • Separating funnel (2 l) • Acetonitrile – HPLC quality • Evaporative flask • Sodium sulphate, granular, • Three Ball Synder column anhydrous • Kuderna- Danish Apparatus • Silica Gel – 100/200 mesh • Water bath (60-65 ̊C) • Stock standard solution • Std. PAHs Solutions – a)100 μg/ml of naphthalene, acenaphthylene, fluorine, phneanthrene and anthracene. b)5μg/ml Benzo (k) Fluoranthene PM/13428/ 3 January 2023 10 URANIUM 5.3, Sl. No. x) of Table 3 IS 3025(Part 65) or IS 14194 (Part 3) i) Inductively coupled plasma mass spectrometry (ICP- MS) method

Standard:IS 13428:2005
Gazetted SpecificationAnnex K of IS 13428 · clause 0.5
Official Gazette Text

ii) Uranium Fluorimeter method i) Inductively Coupled Plasma Mass Spectrometry (ICP-MS) ii) Uranium Fluorimeter/Analyser  Uranium Fluorimeter  Platinum dishes  Platinum Wire Gauge  Fisher Burner  Platinum tipped forceps  Micropipette 0.5 ml  Syringe 5 ml  Ion-exchange column  Infrared Lamp of maximum 500W  Muffle furnace  Hot plate  Water, Grade 1  Nitric acid  Hydrochloric acid  Sulphuric acid  Hydrogen peroxide  Multi-element standard solutions OR  Reagent grade Sodium Fluoride (NaF) and Sodium Carbonate (Na 2 CO 3 )  Uranium standard  Hydrochloric acid  Nitric Acid  Distilled water *Note: Besides listed Equipments/Apparatus/Chemicals, following accessories are essential part of a chemical lab: i) General glass wares like Pipettes Burette, Conical flasks, Beakers, Measuring cylinders, Volumetric flasks, (of different volumes) ii) Provision for distilled/double distilled water iii) Fuming Hood and sink with tap in the lab # The list does not cover the requirements of Pesticide Residues and Radio Active Residues as these requirements are to be got tested from outside approved lab. PM/ 13428/3 January 2023 D - MICROBIOLOGICAL REQUIREMENTS General microbiological lab equipments **

Standard:IS 13428:2005
Gazetted SpecificationAnnex K of IS 13428 · clause 0.01
Official Gazette Text

• Hot air oven (capable of 160 to 180 ºC). • Autoclave (capable of 15 psi/ 121 ºC) of suitable size as per need. • Weighing Balance with least count 0.01 g (least count 0.001 g, if Tergitol-7 agar medium or Crystal violet neutral red bile lactose (VRBL) agar is being prepared in house). • pH meter with least count 0.1 pH unit. • Laminar air flow chamber OR Class II Biosafety Cabinets shall be used for product testing and reference culture in microbiology laboratories. • Hot plate for media preparation. • Membrane filtration assembly (including sterilized membrane filters of 47 mm to 50 mm diameter with 0.45 μm pore size, vacuum pump (for applying vacuum of about 70 kPa) and forceps with rounded tips). • Inoculation loop/needle. • Bunsen burner with LPG cylinder. • Thermostatically controlled water bath. • Air conditioner (recommended) • Refrigerator • Colony counting equipment (recommended) • General glasswares including, petri dishes (made of glass or plastic), volumetric pipettes (of capacity 1 ml and 10 ml), flasks, test tubes, culture bottles, funnels, glass rod, measuring cylinders. • Thermometer with least count, at least four times smaller than the range of required maximum permissible tolerance shall be used)

Standard:IS 13428:2005
Gazetted SpecificationAnnex K of IS 13428 · clause 6.1.1
Official Gazette Text

• Filter paper • Cotton  Ready-to-use microbiological culture plates may also be used against the medias, as mentioned in the table below PM/13428/3 January 2023 SI. No. Parameter Clause Ref. Referred Method of Test Test Equipment/Apparatus ** Chemicals/Media/Reagents ** (1) (2) (3) (4) (5) (6) 1 Escherichia coli (or thermotolerant bacteria) 6.1.1 of IS13428 IS 15185 /ISO 9308-1 • General microbiological lab equipments (as listed above) • Incubator capable of maintaining (36+2) 0 C • Equipment, for membrane filtration • Membrane filters • Disinfected forceps, for handling of membrane filters. • @Incubator capable of maintaining 44°C • Microscope and Glass slides (for Gram staining) • Distilled water • Chromogenic Coliform Agar (Enzymatic digest of casein 1.0g, Yeast Extract 2.0g, Sodium chloride 5.0g, • Sodium dihydrogen phosphate x 2H2O 2.2g, • Disodium Hydrogen Phosphate 2.7g, • Sodium pyruvate 1.0g, • Sorbitol 1.0g, • Tryptophane 1.0g, 6-chloro 3 indoxyl Beta D Galactopyranoside 0.2g, 5- Bromo 4-Chloro 3Indoxyl Beta D Glucuronic Acid 0.1g, • Iso propyl Beta D thiogalactopyranoside (IPTG) 0.1g, • Bacteriological Agar 9-18g • Water 1000ml • pH 6.8±0.2 at 25°C. • Oxidase reagent:

Standard:IS 13428:2005
Gazetted SpecificationAnnex K of IS 13428 · clause 7.2
Official Gazette Text

PM/13428/3 January 2023 • N,N,N’,N’- Tetramethyl p phenylenediamine dihydrochloride 0.1g, • Water 10ml • Tryptone Soya Agar: • Tryptone 15.0g, • Soya Peptone 5.0g, • Sodium Chloride 5.0g, • Agar 15-25g, • Water 1000ml • pH 7.2±0.2 at 25°C • @Medium for indole production • @Kovac’s reagent (for indole test) • Gram stain – (Methyl violet or Crystal violet, Iodine, Potassium iodide; Neutral red, Acetic acid, Ethanol) 2 Coliform Bacteria 6.1.2 of IS i) Reference • General microbiological lab equipments • Distilled water 13428 : method (as listed above) 2005 • Incubator capable of operating at 37 ºC ± • Crystal violet neutral red bile IS 5401 (Pt. 1) 1 ºC lactose (VRBL) agar – /ISO 4832 • Petri dishes, made of glass or plastic, of • (Enzymatic digest of animal diameter 90 mm to 100 mm tissues, Yeast extract, Lactose, • Total-delivery pipettes, having nominal Sodium chloride, Bile salts, capacities of 1ml Neutral red, Crystal violet, • Water bath, or similar apparatus, capable Agar) of operating at 44 to 47°C • Colony-counting equipment, consisting of an illuminated base and a mechanical or electronic digital counter. PM/ 13428/ 3 January 2023 • Test tubes of dimensions approximately 16 mm x 160 mm •

Standard:IS 13428:2005
Gazetted SpecificationAnnex K of IS 13428 · clause 6.8
Official Gazette Text

@ Brilliant green lactose bile • Durham tubes of dimensions appropriate broth – (Enzymatic digest of for use with the test tubes casein, Lactose, Dehydrated ox • Bottles or flasks, for boiling and storage bile, Brilliant green) of culture media ii) IS 15185 • General microbiological lab equipments • Distilled water /ISO 9308-1 (as listed above) • Sample quantity : 50 ml • Incubator, thermostatically controlled at (36 ± 2) °C. • Chromogenic Coliform Agar • Equipment, for membrane filtration (Enzymatic digest of casein 1.0g, Yeast Extract 2.0g, • Membrane filters Sodium chloride 5.0g, • Disinfected forceps, for handling of • Sodium dihydrogen phosphate membrane filters. x 2H2O 2.2g, • @Incubator capable of maintaining 44°C • Disodium Hydrogen Phosphate • Microscope and Glass slides (for 2.7g, Gramstaining) • Sodium pyruvate 1.0g, • Sorbitol 1.0g, • Tryptophane 1.0g, 6-chloro 3 indoxyl Beta D Galactopyranoside 0.2g, 5- Bromo 4-Chloro 3Indoxyl Beta D Glucuronic Acid 0.1g, • Iso propyl Beta D thiogalactopyranoside (IPTG) 0.1g, • Bacteriological Agar 9-18g • Water 1000ml • pH 6.8±0.2 at 25°C. • Oxidase reagent: PM/ 13428/ 3 January 2023 • N,N,N’,N’- Tetramethyl p phenylenediamine dihydrochloride 0.1g,

Standard:IS 13428:2005
Gazetted SpecificationAnnex K of IS 13428 · clause 7.2
Official Gazette Text

• Water 10ml • Tryptone Soya Agar: • Tryptone 15.0g, • Soya Peptone 5.0g, • Sodium Chloride 5.0g, • Agar 15-25g, • Water 1000ml • pH 7.2±0.2 at 25°C • @Medium for indole production • @Kovac’s reagent (for indole test) • Gram stain – (Methyl violet or Crystal violet, Iodine, Potassium iodide; Neutral red, Acetic acid, Ethanol) 3 Sulphite reducing

Standard:IS 13428:2005
Gazetted SpecificationAnnex C of • General microbiological lab equipments • Distilled water · clause 6.1.4
Official Gazette Text

anaerobes 6.1.4 of IS13428 (as listed above) • Differential reinforced IS13428 : • Sample quantity : 50 ml clostridial medium (DRCM) – 2005 • Screw cap bottles or vials and stoppers of Double strength and Single boron silicate glass of capacities 100 ml Strength (if necessary) • Water bath capable at 75 ± 5 °C. (Peptone tryptic digest of meat • Iron wire , Meat extract, Yeast extract, • Incubator (37 ºC ± 1 ºC) Starch, Hydrated sodium • Appropriate method to hermetically seal acetate, Glucose, L- cysteine- the vial or anaerobic systems hydrochloride, Sodium hydroxide) • Anaerobic jar assembly (recommended) • Sodium sulphite • Iron (III) citrate PM/ 13428/ 3 January 2023 4 Pseudomonas

Standard:IS 13428:2005
Gazetted SpecificationAnnex D of • General microbiological lab equipments · clause 6.1.5
Official Gazette Text

• Distilled water • Medium for determination of presumed Pseudomonas aeruginosa – (DL asparagine, L proline, Anhydrous dipotassium hydrogen phosphate, Magnesium sulphate heptahydrate, Anhydrous potassium sulphate, Ethanol) • @ Confirmatory medium (Milk agar medium) – [Skim milk powder, Bacteriological yeast extract, Peptone, Sodium chloride, Agar hexadecyltrimethyl ammonium bromide (centrimide)] • @ Clause D-10 (NOTE) of IS 13428 : 2005 specifies confirmation of non- pigmented strains as a further step, if required. Annex 2D of IS 13428 : 2005 specifies biochemical characteristics to be tested for this purpose. • No specific apparatus, media and reagents have been specified for the same. It is specified that commercially available identification kits may be used for this.For example Gram Staining Kit, Spore Staining Kit, Reagent for Oxidase test, Hydrogen Peroxide for Catalase Test, aeruginosa 6.1.5 of IS13428 (as listed above) IS13428 : • Screw capped bottles 2005 • Incubator (37 ± 1° C) • @Incubator, capable of being maintained at 42 ± 0.5° C • @Incubator 4° C • UV cabinet fitted with UV lamp emitting light of wavelength 360 ± 20 nm • Cellulose acetate or nitrate membrane of pore size 0.22 μm (for alternate

Standard:IS 13428:2005
Gazetted SpecificationAnnex D of • General microbiological lab equipments · clause 0.5
Official Gazette Text

sterilization of ethanol) • @ Incubator, capable of being maintained at 42 ± 0.5° C PM/ 13428/ 3 January 2023 Hugh and Leifson Medium, Media for Nitrate Reductase Test, for Acetamide Deaminase activity, for Gelatin Liquification and for Starch Hydrolysis. 6 Yeast and IS 5403 • General microbiological lab equipments • Distilled water Mould 6.1.7 of (as listed above) • Yeast extract-dextrose- IS13428 • Incubator (25 ± 1 ºC) chloramphenicol-agar medium • – (Yeast extract, Dextrose, Chloramphenicol or Oxytetracycline hydrochloride, Agar) ** NOTES Note 1 – The list does not cover the following requirements, as these parameters are to be tested from outside approved lab: i) Faecal streptococci and Staphylococcus aureus. ii) Salmonella and Shigella. iii) Vibrio cholera and V. parahaemolyticus. Note 2 – General Microbiological Lab Equipments as listed are common for various microbiological tests. Other additional equipments required for specific test methods are indicated against each parameter. Note 3 – For preparation of culture media and reagents ingredients of uniform quality and chemicals of analytical reagent grade should be used. Alternatively, commercially available media and reagents may be used provided their composition comply with those given in Indian Standards

Standard:IS 13428:2005
Gazetted SpecificationAnnex D of • General microbiological lab equipments · clause 4.1
Official Gazette Text

Note 4 – Disposable glassware may be accepted as an alternative to re-usable glassware. Note 5 – All efforts have been made to compile the list as per the respective standards exhaustively covering all the required test equipments, apparatus and chemicals. However, in case any omission or incorrectness is noticed while referring, the same may be conveyed to CMD immediately for suitable actions. The marked equipments/ chemicals and media are required for confirmatory tests of respective microorganisms. The confirmatory test may be dispensed with/omitted, provided the licensee undertakes to start corrective actions based on presumptive presence of microorganisms. PM/ 13428/ 3 January 2023 E - REQUIREMENTS FOR BOTTLES/CONTAINERS FOR PACKAGED WATER SI. No. Clause No. of IS 15410:2003 Specified Requirement Test Facility Requirement Range and Accuracy/ Least Count (If and as Applicable) Method of Test/ Remarks (If any) 1 4.1 Material --- ---- Raw Material conformity to ISs is indicated 2 4.2 4.2.1 Design, Shape and Dimensions Visual ----- 3 4.3 4.3.1 4.3.2 Manufacture, Workmanship, Finish and Appearance Visual ------- --------- To adhere GMP -- 4 4.4 Capacity Weighing Balance Suitable range with ,

Standard:IS 13428:2005
Gazetted SpecificationAnnex D of • General microbiological lab equipments · clause 0.1
Official Gazette Text

LC 0.1 g for Balanceor1 ml for Cylinder Cl 5 of IS 2798 5 4.5 Wall Thickness Micrometer Suitable Range with LC 0.02 mm Cl 4.5 of IS 2798 6 4.6.2 Transparency Transparency/ Haze Meter Range upto 100 %,LC 1%

Standard:IS 13428:2005
Gazetted SpecificationAnnex A of IS 15410 · clause 4.6.3
Official Gazette Text

7 4.6.3 Leakage Test Vibration Leakage Tester as per Cl. 6.2.1 of IS 2798 Reservoir Air Pressure Leakage Tester - Cl 6 of IS 2798 8 4.6.4 Drop Test Drop Tester with height of 0.5 m Cl 8 of IS 2798 9 4.6.5 Migration Test Oven/Water Bath Hot Plate Analytical Balance SS Evaporating Dish Capable of maintaining40+2° C IS 9845 PM/ 13428/ 3 January 2023 Dessicator Glass Beaker, pyrex, 1000 ml Pouch Sealing Machine 10 4.6.6 Water Potability test Conditioning Chamber Capable of maintaining 38+2° C

Standard:IS 13428:2005
Gazetted SpecificationAnnex B of IS 15410 · clause 6.1
Official Gazette Text

F- REQUIREMENTS FOR POLYETHYLENE FLEXIBLE POUCHES FOR PACKAGED WATER SI. Clause No. Specified Requirement Test Facility Requirement Range and Method of Test/ No. of IS Accuracy/ Least Remarks (If any) 15410:2003 Count (If and as Applicable) Clause 6.1 Requirements for Films 1 6.1.1 Description Visual --------------------- 2 6.1.2 Film Form Visual --------------------- 3 6.1.3 Winding of Film Visual --------------------- 4 6.1.4 Odour Olfactory --------------------- 5 6.1.5 Thickness Dead Weight Dial Suitable Range with A-2 of IS 2508 (65± 5μ/ 75± 5μ) Micrometer LC1μ 6 6.1.6 Width (in mm) Scale Suitable Range, LC 1 mm 7 6.1.7 Overall Migration Oven/Water Bath Capable of IS 9845 Hot Plate maintaining 40±2 o C Analytical Balance SS Evaporating Dish Dessicator Glass Beaker, pyrex, 1000 ml Pouch Sealing Machine PM/ 13428/ 3 January 2023 8 6.1.8 Tensile Strength Tensile Testing Machine of suitable LC 0.01 kN A-4 of IS 9845 range 9 6.1.9 Elongation at break Tensile Testing Machine of suitable LC 0.01 kN A-4 of IS 9845 range 10 6.1.10 Dart Impact Resistance Dart Impact Tester with Drop Height Set of weights (Min. A-6 of IS 9845 of 66 cm Impact failure load : 2.20 N) Clause 7 Requirements for Pouches 11 7.1 Vibration Leakage Test Vibration Table Temp. - Ambient Table conforming to or27 ± 2 0 C in case of dispute IS 7028 (Pt 2) Frequency of vibration 2 Hz 12 7.2 Water Potability Test Oven/Heating Arrangement Pouch Capable of Sealing Machine maintaining 38±2 o C 13 7.3 Stack Load Test Flat Wooden Plank Set of weights for20

Standard:IS 13428:2005
Gazetted SpecificationAnnex F of IS 15609 · clause 7.4
Official Gazette Text

Temp. - Ambient or N to 200 N 27±2 0 C in case of dispute 14 7.4 Drop Test Arrangement for flat drop from 1.2 m ---------- Annex G of IS 15609 height 15 7.5 Ink Adhesion Test for Printed Pressure Sensitive Tapes or Cello- 25 mm wide tape

Standard:IS 13428:2005
Gazetted SpecificationAnnex H of IS 15609 · clause 7.6
Official Gazette Text

Pouch Tape Arrangement for pulling tape at 10mm/s at about 90 o 16 7.6 Product Resistance Test for Paper Tissue ------------- Annex J of IS 15609 Printed Pouch Clause 8 Construction 17 8 Construction Visual -------------- PM/ 13428/ 3 January 2023

Standard:IS 13428:2005
Gazetted SpecificationANNEX F · clause 1.0
Official Gazette Text

SCHEME OF INSPECTION AND TESTING FOR PACKAGED NATURAL MINERAL WATER ACCORDING TO IS 13428: 2005 1.0 LABORATORY -A laboratory shall be maintained which shall be suitably equipped and staffed with competent testing person(s) to carry out the different tests in accordance with the methods given in the Indian standards. Testing person(s) shall be science/engineering graduate from disciplines such as chemistry/chemical engineering/ microbiology/ biotechnology/ biochemistry/ food technology/ botany and other biological/ life sciences. Engineering graduates from disciplines such as chemical engineering may also be engaged as testing persons. 1.1. The manufacturer shall prepare and implement a calibration plan for the test equipment. 2. TEST RECORDS –The manufacturer shall maintain test records for the tests carried out to establish conformity. 3.0 LABELLING AND MARKING - The Standard Mark, as given in the Schedule of the Licence shall be clearly marked legibly and indelibly on the label of the bottle/container or on the pouch as the case may be, provided always that the material on which this Mark is applied conforms to every requirement of the specification. The dimension of standard mark shall be in accordance with specified design. 3.1 PACKING – The Packaged Natural Mineral Water shall be packed as per clause 3.2, clause 7 and

Standard:IS 13428:2005
Gazetted SpecificationAnnex B of IS 13428:2005. The pouches and bottles/containers shall be supplied in secondary packaging · clause 3.2
Official Gazette Text

as agreed to between the purchaser and the supplier. 3.2 Packaged Natural Mineral Water packed in Paper based multilayer laminated/extruded composite cartons shall conform to IS 17753 and aluminum cans shall conform to Indian standard on 'Aluminum cans for packaged natural mineral water and packaged drinking water — Specification [Doc: PGD 38 (20182)] as per provisions of Cl. 7.1.2 of IS 13428:2005. 3.3 All packaging materials of plastic origin shall pass the overall migration, colour migration and specific migration limits for toxic substances as laid down in IS 15410 as per provisions of Cl. 7.1.3 of IS 13428:2005. 3.4 MARKING – In addition to the Standard Mark as per clause 8 of IS 13428:2005 the following information shall be given legibly & indelibly on each bottle/container or its label or directly printed on the pouch/bottle/container. i. Name of the product (i.e. Natural Mineral Water) ii. Supplementary designations, if any; iii. Name and full address of the processor (i.e. manufacturer); iv. Brand Name, if any; v. Batch or Code Number/Control Unit No.; vi. Date of manufacture/ packaging’ and ‘Expiry/Use by; vii. Best before date (optional); viii. Net quantity;

Standard:IS 13428:2005
Gazetted SpecificationAnnex B of IS 13428:2005. The pouches and bottles/containers shall be supplied in secondary packaging · clause 3.4.1
Official Gazette Text

ix. Location and name of the source of natural mineral water. x. Direction for storage; xi. Keep the container away from direct sunlight; and xii. Any other information required under the Legal Metrology(Packaged Commodity) Rules, 2011 and the Food Safety and Standards (Packaging and Labeling) Regulations 2011. xiii. Recycling symbol as per IS 14534 and 14535 xiv. BIS website details: www.bis.gov.in 3.4.1 Minimum height of the BIS Standard Mark on different pack sizes of Packaged Natural Mineral Water shall be as under: S. No. Size of Container Min height of BIS Standard Mark* 1 Pouch/Cups/bottle(250 ml capacity & 5mm below) 2 Bottles upto 500ml capacity & below 7.5mm (but greater than 250 ml capacity) 3 Bottles more than 500ml capacity 10mm PM/ 13428/ 3 January 2023 4 All re-useable Jars 15mm (* other dimensions of the BIS Standard Mark shall be in appropriate proportions as per BIS guidelines). 3.5 Each secondary packing of pouches/bottles/containers shall be marked with the following, except where such secondary packing is transparent and the markings on the pouches/bottles/containers are legible through the secondary packing: i. Indication of the source of manufacture i.e. manufacturer’s name and address;

Standard:IS 13428:2005
Gazetted SpecificationAnnex B of IS 13428:2005. The pouches and bottles/containers shall be supplied in secondary packaging · clause 3.6
Official Gazette Text

ii. Number of pouches/bottles/containers iii. Brand name, if any iv. Nominal capacity; v. Batch No. or Code No. 3.6 LABELLING PROHIBITIONS -The label on the bottles/containers/pouches and/or the secondary packaging shall not contain claims which are prohibited as per clause 8.2 of IS 13428:2005. 3.7 Shelf life: Declared shelf life for Packaged Natural Mineral Water in all type of packing materials shall not be less than 30 days. (also see Table 1 and Note 8 under Table 1) 3.8 Brand names: The labels conforming to the marking details as mentioned in clause 8 of IS 13428 along with the brand names are to be submitted by licensees to BIS for information only, which will only be noted by BIS for records. The compliance of such labels to the requirement of clause 8 shall be ensured by licensees. However, in case non-compliance to Clause 8 is observed by BIS and communicated in writing to licensee, licensee shall make necessary rectification and resubmit the label for confirmation to concerned BIS Branch Office within 15 days. Decision of BIS regarding whether labeling is complying or not with clause 8 of IS 13428 shall be final. 4.0 LEVELS OF CONTROL -The tests as indicated in Table 1 and at the levels of control specified

Standard:IS 13428:2005
Gazetted SpecificationAnnex B of IS 13428:2005. The pouches and bottles/containers shall be supplied in secondary packaging · clause 5.0
Official Gazette Text

therein, shall be carried out on the whole production of the factory covered by this Scheme and appropriate records maintained in accordance with clause 2 of this Scheme. Entire production which conforms to the Indian Standard and covered by the licence shall be marked with Certification Mark of the Bureau. 5.0 CONTROL UNIT - For the purpose of this Scheme, the quantity of packaged natural mineral water treated/processed from each processing line and filled/packed in one day shall constitute a Control Unit. 5.1 On the basis of tests and analysis results, the decision regarding conformity or otherwise of a Control Unit to the given requirements shall be made. 5.2 In respect of all other clauses of the Standard (other than those mentioned under Levels of Control– Table 1 of this Scheme) the factory shall maintain appropriate controls and checks to ensure that their product conforms to the requirements of the standard. 6.0 Microbiological Requirements - If any failure is noticed in any of the microbiological requirements, control units available in the stock shall be rechecked and released into the market only after conformity is ensured. 6.1 The licensee shall take immediate corrective actions, which would involve complete investigation of

Standard:IS 13428:2005
Gazetted SpecificationAnnex B of IS 13428:2005. The pouches and bottles/containers shall be supplied in secondary packaging · clause 7.0
Official Gazette Text

the reasons for contamination and non-conformity. The manufacturer should re- start marking and dispatch only after the completion of satisfactory corrective actions and availability of satisfactory results of all microbiological tests as applicable for each control unit, for next 2 consecutive control units. The manufacturer shall keep complete records of such instances for review by BIS for minimum period of 5 years. 7.0 SOURCE WATER - The source water used in production of Packaged Natural Mineral Water shall be initially tested for Organoleptic and physical parameters (Table 1), Chemical requirements (Table 2), and all microbiological requirements possible to be tested in house. Subsequently, its quality may be regularly assessed at least once in three months through in- house testing for Colour, Odour, Taste, Turbidity, pH, Total Dissolved Solids and Microbiological requirements. In addition, any other requirements as considered necessary for process control, are to be tested where the incidence of their presence in higher levels has been detected during the previous tests. PM/ 13428/ 3 January 2023 7.1 The permitted treatment under clause 3 and 4 of IS 13428 shall only be carried out on condition that

Standard:IS 13428:2005
Gazetted SpecificationAnnex B of IS 13428:2005. The pouches and bottles/containers shall be supplied in secondary packaging · clause 7.2
Official Gazette Text

the mineral content of water is not modified. Whenever, the quality of processed mineral water is found to be not meeting the requirements of IS 13428 for the tested parameters, the source water shall be checked again for such parameters in which failure is observed for deciding upon the necessary controls to be exercised for conformance of quality of processed water to IS 13428. 7.2 In case non-conformity is observed for radioactive residues, the source of raw water shall be abandoned and water shall be recalled immediately. 7.3 As and when there is change in source water, it shall be intimated to BIS. The raw water collected from the new source shall be tested in accordance with Clause 7 as above and the processed mineral water produced from such source water shall be tested for conformity to IS 13428 from BIS recognized outside lab. The reports of source water and the product water produced from the new source shall be submitted to BIS for approval before commissioning for regular production and marking. 8.0 Plastic Jars/Bottles/Containers - The plastic containers used for packing the material shall conform to IS 15410:2003. The conformity assessment shall be carried in accordance with the levels of controls

Standard:IS 13428:2005
Gazetted SpecificationAnnex B of IS 13428:2005. The pouches and bottles/containers shall be supplied in secondary packaging · clause 8.1
Official Gazette Text

as given under Table 2. 8.1 In addition, the top lid for glasses/cups shall be of suitable peelable structure in accordance with Clause 4.2.1 of IS 15410:2003. 8.2 Pouches–The polyethylene film and pouches shall conform to IS 15609. The conformity assessment shall be carried in accordance with the levels of controls as given under Table3. 8.3 Glass Bottles - IS 11984 has been specified as a reference Indian Standard for glass bottles. However, if any manufacturer intends to use glass bottles for packaging, it shall be included in the licence. The separate processing line for filling the glass bottles may be verified by BIS during the next inspection and necessary steps in the process for ensuring sterility of bottles may be adopted like steam sterilizing, hot water rinsing, UV sterilization or combination thereof. In case of lug caps containing plastic lining, food grade certificate or OSL test report for migration testing may be accepted. 8.4 Paper based multilayer laminated/extruded composite cartons and aluminum cans - Paper based multilayer laminated/extruded composite cartons shall conform to IS 17753. The conformity assessment shall be carried in accordance with the levels of controls as given under Table 4.

Standard:IS 13428:2005
Gazetted SpecificationAnnex B of IS 13428:2005. The pouches and bottles/containers shall be supplied in secondary packaging · clause 9.0
Official Gazette Text

Aluminum cans shall conform to Indian standard on 'Aluminum cans for packaged natural mineral water and packaged drinking water — Specification' [Doc: PGD 38 (20182)]. 9.0 REUSED CONTAINERS – Licensee shall ensure use of only such jars for packing the product water whose transparency continues to meet the requirements as per IS 15410 even after its repeated use. Jars which get soiled, de-shaped and/or mutilated during the course of use and refilling shall not be used. 9.1 Water to be used for the purpose of cleaning etc. IS 4251:1967 may be followed as Good Manufacturing practices. 10.0 HYGIENIC CONDITION - The Natural Mineral water shall be collected, processed, handled, stored, packed and marketed in accordance with the hygienic practices given under Annex B of IS 13428:2005. Other clauses shall also be complied in day to day production and quality control activities. Schedule for each activity for this purpose shall be displayed prominently in the factory premises and records of compliance shall be maintained for scrutiny by the Bureau. The hygienic conditions shall also be maintained at the site of water source. A check list for good hygienic practices and food safety system

Standard:IS 13428:2005
Gazetted SpecificationAnnex B of IS 13428:2005. The pouches and bottles/containers shall be supplied in secondary packaging · clause 11.0
Official Gazette Text

for packaged drinking water processing units is given in Annex H of this product manual. 11.0 REJECTION - Disposal of non-conforming product shall be done in such a way so as to ensure that there is no violation of provisions of BIS Act, 2016. A separate record providing the detailed information regarding the rejected control units and mode of their disposal shall be maintained. Such material shall in no case be stored together with that conforming to the specification. PM/ 13428/ 3 January 2023 IS 13428:2005 PACKAGED NATURAL MINERAL WATER TABLE 1 LEVELS OF CONTROL (Para 4 of the Scheme of Inspection and Testing) TEST DETAILS Test equipment LEVELS OF CONTROL REMARKS Clause Requirement Test Method requirement No. of Frequency Clause Reference R: required (or)S: Sub- Sample contracting permitted 6.1 Microbiological Requirement 6.1.1 Escherichia coli -- IS 15185 R One Each control unit 6.1.2 Coliform Bacteria -- IS 5401 (Part-1)* R One Each control unit or IS 15185 6.1.3 Faecal Streptococci and Staphylococcus -- IS 5887 (Part-2)* S One Once in a month aureus or IS 15186 6.1.4 Sulphite Reducing Anaerobes -- R One Each control unit 13428 6.1.5 Pseudomonas aeruginosa --

Standard:IS 13428:2005
Gazetted SpecificationAnnex D of IS · clause 6.1.6
Official Gazette Text

R One Each control unit 13428 6.1.6 Yeast &Mould -- IS 5403 R One Each control unit 6.1.7 Salmonella and Shigella -- IS 15187 & IS S One Once in a month 5887 (Part-7), respectively 6.1.8 Vibrio cholera and V. parahaemolyticus -- IS 5887 (Part-5) S One Once in a month PM/ 13428/ 3 January 2023 TABLE 1 (continued) TEST DETAILS Test equipment LEVELS OF CONTROL REMARKS Clause Requirement Test Method requirement No. of Frequency Clause Reference R: required (or)S: Sample Sub-contracting permitted 6.2 and Table 1 i) Colour - IS 3025 (Part 4) R One Each Control Unit See Note 2 -do- ii) Odour - IS 3025 (Part 5) R One Each Control Unit -do- -do- iii) Taste - IS 3025 (Part 8) R One Each Control Unit -do- -do- iv) Turbidity - IS 3025 (Part 10) R One Each Control Unit -do- -do- v) Total Dissolved Solids - IS 3025 (Part 16) R One Each Control Unit See Note 3 -do- vi) pH - IS 3025 (Part 11) R One Every four hours See Note 2 6.2 and Table 2 i) Nitrate (as NO3) - IS 3025 (Part 34) R One Once in a week See Note 4 -do- ii) Nitrite (as NO2) - IS 3025 (Part 34) R One Once in a week -do- -do- iii) Sulphide (as H2S) - IS 3025 (Part 29) R One Once in a week -do- -do- iv) Manganese (as Mn) - IS 3025 (Part 59)* or IS

Standard:IS 13428:2005
Gazetted SpecificationAnnex D of IS
Official Gazette Text

R One Once in a week -do- 3025 (Part 2) -do- v) Copper (as Cu) - IS 3025 (Part 42)* or IS R One Once in a week -do- 3025(Part 2) -do- vii) Fluoride (as F) - IS 3025 (Part 60) S One Once in six months See Note 6 viii) Barium (as Ba) - R One Once in a week See Note 4 13428* or IS 15302 or IS 3025 (Part 2) -do- ix) Antimony (as Sb) - S One Once in a month See Note 5 or IS 15303 -do- x) Borates (as B) -

Standard:IS 13428:2005
Gazetted SpecificationAnnex J of IS 13428* or · clause 6.2
Official Gazette Text

S One Once in a month -do- IS 3025 (Part 2) -do- xi) Silver (as Ag) - Annex K of IS 13428 S One Once in six months See Note 6 -do- xii) Chloride (as Cl) - IS 3025 (Part 32) R One Each control unit See Note 2 -do- xiii) Sulphate (as SO4) - IS 3025 (Part 24) R One Each control unit See Note 2 -do- xvi) Magnesium (as Mg) - IS 3025 (Part 46)* or R One Once in a week See Note 4 IS 3025 (Part2) PM/ 13428/ 3 January 2023 -do- xv) Calcium (as Ca) - IS 3025 (Part 40)* or IS R One Once in a week See Note 4 3025 (Part 2) -do- xvi) Sodium (as Na) - IS 3025 (Part 45)* or IS S One Once in six months See Note 6 3025(Part 2) -do- xvii) Alkalinity (as HCO3) - IS 3025 (Part 23) R One Each control unit See Note 2 -do- xviii) Selenium (as Se) - IS 15303* or IS 3025 S One Once in six months See Note 6 (Part 56) -do- xix) Mineral Oil - 6 of IS 3025 (Part 39) S One Once in a month See Note 5 -do- xx) Phenolic compounds - 6 of IS 3025 (Part 43) S One Once in a month See Note 5 (as C6H5OH) -do- xxi) Anionic surface active - Annex L of IS 13428 S One Once in a month See Note 5 agents (as MBAS) 6.2 and Table 3 i) Arsenic (as As) - IS 3025 (Part 37) S one Once in six months See Note 6 -do- ii) Cadmium (as Cd) - IS 3025 (Part 41) S one Once in six months -do- -do- iii) Cyanide (as CN) - 2 of IS 3025 (Part 27) S one Once in six months -do- -do- iv) Chromium (as Cr) -

Standard:IS 13428:2005
Gazetted SpecificationAnnex K IS 13428* or IS · clause 6.2
Official Gazette Text

S one Once in six months -do- 3025 (Part 2) -do- v) Mercury (as Hg) - IS 3025 (Part 48) S one Once in six months -do- -do- vi) Lead (as Pb) - IS 3025 (Part 47) S one Once in six months -do- -do- vii) Nickel (as Ni) - Annex M IS 13428 S one Once in six months -do- -do- viii) Polychlorinated - Annex N of IS 13428 S one Once in six months -do- Biphenyl (PCB) -do- ix) Polynuclear aromatic - APHA 6440 I S one Once in six months -do- hydrocarbons x) Uranium -=-- IS 3025(Part 65)* or IS 14194 (Part 3) S one -do- -do- PM/ 13428/ 3 January 2023 TEST DETAILS Test equipment LEVELS OF CONTROL REMARKS Clause Requirement Test Method requirement No. of Frequency R: required (or)S: Sample Clause Reference Sub-contracting permitted 6.2 and Table 4 i) Alpha emitters - IS 14194 (Part 2) S one Once in five years -do- ii) Beta emitters - IS 14194 (Part 1) S one Once in five years 6.3 Pesticide Residues - Annex P of IS 13428**S One See Note 1 below Once in a year - Shelf Life Assessment B 6.9 Annex B of IS 13428 R Once in six months each See Note 8 below type of container shall be tested for shelf life assessment In case of dispute, methods given at column 4 and wherever indicated by “*” shall be the referee method.

Standard:IS 13428:2005
Gazetted SpecificationAnnex K IS 13428* or IS
Official Gazette Text

**Shall be got tested from BIS recognized laboratory using internationally established test method as specified in Annex P of IS 13428 : 2005 Note 1: For tests with frequency of once in a year, in case any failure is observed, in the requirement of Pesticide Residues, then the next 3 consecutive samples (factory/market) of that licence shall be tested for all tests including Pesticide Residues(except Radioactive residues), till the 3 consecutive samples are found conforming to all requirements tested including pesticide residues. Note 2: In case of failure in any requirement with frequency of each control unit like colour, odour, taste, turbidity, Chloride, Sulphate, Alkalinity, after taking corrective action the frequency to be increased from each control unit to every four hours for one month. Thereafter frequency of each control unit may be restored if all the samples during the month are found passing. For pH, in case of failure, after taking corrective action, the frequency to be increased from every four hours to every hour for a week. Thereafter frequency of every 4 hours may be restored if all the samples during the week are found passing. Note 3: In case of failure in total dissolved solid, after taking corrective action, the frequency to be increased from each control unit to every four hours for one month. Thereafter

Standard:IS 13428:2005
Gazetted SpecificationAnnex K IS 13428* or IS
Official Gazette Text

frequency of each control unit may be restored if all the samples during the month are found passing. Note 4: In case of failure in Nitrate, Nitrite, Manganese, Copper, Calcium, Magnesium, Barium and Sulphide, after taking corrective action, the frequency to be increased from once in a week to each control unit for one month. Thereafter frequency of once in a week may be restored if all the samples during the month are found passing PM/13428/ 3 January 2023 Note 5: In case of failure in any requirement like Phenolic Compounds, Mineral Oil, Anionic surface active agents, Antimony, Borate, with frequency of once a month, after taking corrective actions, samples from 2 consecutive control units shall be tested in house or in BIS recognized third party lab. Thereafter frequency of once in a month may be restored if the samples from both control units are found passing. Note 6: In case of failure in any requirement like Fluoride, Silver, Selenium, Sodium, Mercury, Cadmium, Arsenic, Cyanide, Lead, Chromium, Nickel, PCB, PAH, Uranium with frequency of once in six months, the frequency to be increased from once in 6 months to once in 3 months for 6 months. Thereafter frequency of once in 6 months may be

Standard:IS 13428:2005
Gazetted SpecificationAnnex K IS 13428* or IS
Official Gazette Text

restored only if both the samples tested at each quarter are found passing. Note 7: Approved and validated international test methods from ISO/ APHA/ ASTM/ AOAC/EPA/EN may also be followed for performing tests given in Table 2 & 3 of IS 13428 : 2005. In case of dispute, methods given at column 4 and wherever indicated by “*” shall be the referee method. Note 8: Shelf Life testing shall be done in house for all possible tests for organoleptic, physico-chemical, chemical, and microbiological parameters which are possible to be tested in house as per test methods prescribed in IS 13428. Records of shelf life studies to be maintained. In case of failure, the manufacturer shall review the shelf life declaration and re-declare the suitable revised shelf life. Note-9: Whether test equipment is required or sub-contracting is permitted in column 2 shall be decided by the Bureau and shall be mandatory. Sub- contracting is permitted to a laboratory recognized by the Bureau or Government laboratories empaneled by the Bureau. Note-10: The control unit and levels of control as decided by the Bureau are obligatory to which the licensee shall comply with. Note -11: Whenever, due to failure, the test frequency is increased, the compliance for such frequency levels may be ensured either from in-house or OSL testing of samples.

Standard:IS 13428:2005
Gazetted SpecificationAnnex K IS 13428* or IS
Official Gazette Text

FORM 1 REPORT FOR FOUR HOURLY pH TESTING Date of Production Batch Number/ Control unit number pH Remarks 1 2 3 4 FORM 2 REPORT FOR DAILY/ EACH CONTROL UNIT TESTING PM/13428/ 3 January 2023 Date of Batch Colour Odour Taste Turbidity TDS Chloride Sulphate Alkalinity E.coli Coliform Sulphite Pseudo Yeast Remark monas & Production Number/ Bacteria reducing aerugin Mould control anaerobes osa unit number 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 FORM 3 REPORT FOR WEEKLY & MONTHLY TESTING Date Batch/ Barium Copper Mangan Nitrate Nitrite Calcium Sulphide Magnesium Antimony Borate Phenolic Mineral Oil Anionic Remarks ese Compounds Surface control Active unit no. Agents 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 PM/13428/ 3 January 2023 PM/13428/ 3 January 2023 FORM 4 FORMAT FOR TESTING FROM BIS RECOGNIZED OUTSIDE LABORATORY Month & Year Batch No./DOM Type of packing Dates on which Lab to which Test report Results Remarks sample sent sample sent number & date 1. REPORT FOR MONTHLY TEST i. Faecal streptococci and S. aureus, Salmonella and Shigella, V. cholera and V. parahaemolyticus ii. Mineral Oil, Anionic Surface Active Agents, Phenolic Compounds, Antimony, Borates, 2. REPORT FOR SIX MONTHLY TEST

Standard:IS 13428:2005
Gazetted SpecificationAnnex K IS 13428* or IS
Official Gazette Text

i. Mercury, Cadmium, Arsenic, Cyanide, Lead, Chromium, Nickel, Fluoride, Selenium, Sodium, PCB, PAH. ii. Silver (as applicable) iii. Pesticide Residues 3. REPORT FOR FIVE YEARLY TEST I. Radio Active Residues (Alpha and Beta Emitters) PM/13428/ 3 January 2023 PM/13428/ 3 January 2023 FORM 5 SOURCE WATER TESTING (3 MONTHLY TESTS) Month Source of In-house testing Outside testing (if done) Record of in-house Results Remarks & Year water (if done) testing/outside TR Name of sample TR No. lab sent on & Date FORM 6 RECORD FOR PLASTIC CONTAINERS USED FOR PACKING WATER Date of Type of Name of Quantity Whether Details of outside Results Remarks receipt packing supplier received ISI testing material marked Name of Date of Overall Colour Remaining lab sending migration migration parameters samples as per IS 15410 FORM 7 RECORDS FOR SHELF LIFE ASSESSMENT (SEPARATE FOR EACH TYPE OF CONTAINER BEING USED) Date on which Batch Type of Declared shelf Periodicity of Date of Requirements Results Remarks sample kept No./DOM packing whose life testing Testing Tested sample kept FORM 8 FORMAT FOR PE FILM PM/ 13428/ 3 January 2023 Date of Name of Quantity Details of Descriptio Film Winding Odour Thicknes Width

Standard:IS 13428:2005
Gazetted SpecificationAnnex K IS 13428* or IS
Official Gazette Text

Overall Tensile Elongation Dart Results Remark Receipt Supplier Receive Test report n Form of s Migratio Strength n Impact Film at Break Resistance d n of (No. of from O S Rolls Rolls) Lab. With date (1) (2) (3) (4) (5) (6) (7) (8) (9) (10) (11) (12) (13) (14) (15) (16) FORM 9 FORMAT FOR POUCH TESTING Date of Time of Total quantity Drop Test Stack Load Ink Adhesion of Product Resistance Water Results Remarks Pouch production produced Test Printed Pouches of Potability Production Printed Pouches Test Machine No. 1 2 3 4 Etc. (1) (2) (3) (4) (5) (6) (7) (8) (9) (10) TABLE 2 PM/13428/ 3 January 2023 GUIDELINES ON ENSURING CONFORMITY OF CONTAINERS USED FOR PACKAGED NATURAL MINERAL WATER Type of container Parameters Options for mode of conformity Frequency to be followed by licensee a) Plastic Jars i) Overall migration and colour migration as per Clause 7 of IS 13428 ii) Conformity to IS15410 i) ‘ISI’ marked, OR ii) In-house Test Reports of licensee, if facilities exist; OR iii) BIS recognized outside laboratory Test Report of the samples (not older than 6months from the date of purchase) ; OR iv) Combination of the above. Once in six months, sample from one consignment of plastic jars of each size/material procured from a single

Standard:IS 13428:2005
Gazetted SpecificationAnnex K IS 13428* or IS
Official Gazette Text

source (i.e. supplier) shall be tested as per the modes of conformity given in column 3 (Not required if material is ISI marked) b) Plastic Bottles, Glass/ cups i) Overall migration and colour migration as per Clause 7 of IS 13428 ii) Conformity to IS 15410 i) ‘ISI’ marked OR ii) In-house Test Reports of licensee, if facilities exist OR iii) BIS recognized outside laboratory Test Report of the samples (not older than 6months from the date of purchase) Once in six months, sample from one consignment of plastic bottles/ glasses/ cups of each type/ shape/ capacity/ material procured from a single source (i.e. supplier) shall be tested as per the modes of conformity given in column 3 (Not required if material is ISI marked c) Plastic cap (closures) of containers Overall migration and colour migration as per Clause 7 of IS 13428 i) Declaration/ certificate w.r.t. food grade quality, as permitted under IS13428 , AND ii)In house test report of licensee, if facilities exist ; OR Once in six months, sample from one consignment of plastic caps/closures of each size/material procured from a single source (i.e. supplier) shall be tested as per the modes of conformity given in column 3 (Not

Standard:IS 13428:2005
Gazetted SpecificationAnnex K IS 13428* or IS
Official Gazette Text

required if material is ISI marked) iii) BIS recognized outside laboratory test report of samples (not older than 6months from the date of purchase) PM/ 13428/ 3 January 2023 d) Foil (for sealing of plastic cups/ glasses) Overall migration and colour migration as per Clause 7 of IS 13428:2005 i) Declaration/ certificate w.r.t. food grade quality of the material used for the plastic film, AND Once in six months, sample from one consignment of one consignment of foils procured from a single source (i.e. supplier) shall be tested as per the modes of conformity given in column 3 (Not required if material is ISI marked) ii) In house test report of licensee, if facilities exist OR iii) BIS recognized Outside test report of samples (not older than 6months from the date of purchase) Note : Licensee to keep records of receipt for all types of containers and closures received, along with the corresponding test certificate in case of ISI marked consignment or test reports of samples tested in-house or got tested as per the specified frequency at BIS recognized laboratory, to be verified by BIS during periodic inspections for adequacy of the system being followed by licensee to control quality of packaging material received, accepted, rejected and method of

Standard:IS 13428:2005
Gazetted SpecificationAnnex K IS 13428* or IS · clause 6.1
Official Gazette Text

disposal. PM/ 13428/ 3 January 2023 July 2020 TABLE 3 Levels of control for Polyethylene Flexible Pouches for the packing of Packaged Natural Mineral Water as per IS 15609 TEST DETAILS Test equipment LEVELS OF CONTROL Clause Requirement Test Method requirement Lot size Remarks (Modes of Conformity etc.) R: required No. of Clause Reference (or)S: Sub- Samples contracting permitted 5 Material 5 IS 15609 S One Each consignment of i) ISI Marked, OR Polyethylene film ii) BIS recognized outside laboratory Test Report of the samples, OR iii) Test certificate issued by PE resin supplier. 6.1 Requirement for Polyethylene Film 6.1.1 Description 6.1.1 IS 15609 R One Each roll of All rolls to be checked before using the polyethylene film same for making pouches. All such rolls which do not conform to the requirement shall be rejected 6.1.2 Film Form 6.1.2 -do- R -do- -do- -do- 6.1.3 Winding of film 6.1.3 -do- R -do- -do- -do- 6.1.4 Odour 6.1.4 -do- R -do- -do- -do- 6.1.5 Thickness 6.1.5 -do- R -do- -do- -do- 6.1.6 Width 6.1.6 -do- R -do- -do- -do- 6.1.7 Overall Migration 6.1.7 -do- S -do- i) ISI Marked, OR ii) In house test report, if facility One consignment exist with the licensee OR from each source iii) Outside approved laboratory

Standard:IS 13428:2005
Gazetted SpecificationAnnex K IS 13428* or IS · clause 6.1.8
Official Gazette Text

(i.e. supplier) initially test report of the sample and subsequently If the sample does not conform to the once every six requirement, the consignment shall be months for each rejected. source (i.e. supplier) PM/ 13428/ 3 January 2023 July 2020 Table 3 contd... TEST DETAILS Test equipment LEVELS OF CONTROL Clause Requirement Test Method requirement No. of Lot size Remarks Clause Reference R: required Samples (or)S: Sub- contracting permitted 6.1.8 Tensile strength 6.1.8 -do- S -do- -do- -do- 6.1.9 Elongation of break 6.1.9 -do- S -do- -do- -do- 6.1.10 Dart impact 6.1.10 -do- S -do- -do- -do- resistance 7 Requirement for Flexible Pouches 7.2 Water Potability

Standard:IS 13428:2005
Gazetted SpecificationAnnex J · clause 4.1
Official Gazette Text

-do- R One -do- -do- of printed Pouches [Type here] PM/13428/3 January 2023 Note-1: Whether test equipment is required or sub-contracting is permitted in column 2 shall be decided by the Bureau and shall be mandatory. Sub-contracting is permitted to a laboratory recognized by the Bureau or Government laboratories empaneled by the Bureau. Note-2: Levels of control given in column 3 are only recommendatory in nature. The manufacturer may define the control unit/batch/lot and submit his own levels of control in column 3 with proper justification for the approval by BO Head. [Type here] PM/13428/3 January 2023 TABLE 4 Levels of control for Paperbased Multilayer Laminated/Extruded Composite Cartons (Aseptic and Non-Aseptic) For Processed Liquid Food Products and Beverages as per IS 17753 TEST DETAILS Test equipment LEVELS OF CONTROL Requirement Test Method requirement Lot size Remarks (Modes of Conformity etc.) R: required (or)S: No. of Clause Reference Sub-contracting Samples permitted Material, Cl. 4.1 4.1 IS 17753 S One Each consignment of paper based multilayer composite sheet i) Test Reports from BIS recognized outside laboratory, OR ii) Test certificate issued by supplier Paper Board,

Standard:IS 13428:2005
Gazetted SpecificationAnnex J · clause 4.1.1
Official Gazette Text

Cl. 4.1.1 --- IS 16983/IS 1776/ IS 12999 S One Each consignment i) BIS recognized outside laboratory Test Report of the samples, OR ii) Test certificate issued by supplier Polyethylene, Cl. 4.1.2 --- IS 2508/IS 14500/ IS 10146/ IS 16738 S One Each consignment i) Test Reports from BIS recognized outside laboratory, OR ii) Test certificate issued by supplier Aluminium Foil, Cl. 4.1.3 4.3 of IS IS 8970 IS 8970 and Table 1 of IS 17753 S One Each consignment i) BIS recognized outside laboratory Test Report of the samples, OR ii) Test certificate issued by supplier Caps, Cl. 4.1.4 --- IS 10910 S One Each consignment i) ISI Marked, OR ii) BIS recognized outside laboratory Test Report of the samples, OR iii) Test certificate issued by supplier Printing Inks, Cl. 4.1.6 IS 15495 S One Each consignment i) BIS recognized outside laboratory Test Report of the samples, OR ii) Test certificate issued by supplier Requirement for Paper Based Multilayer Laminated/Extruded Composite Sheets Description, Cl. 5.1 5.1 IS 17753 R One Every hour Overall Migration, Cl. 5.2.1 ---- IS 9845 R -do- Once in a fortnight -do- Specific Migration ---- IS 9845 and IS 3025(Part-2)/ R -do- Every month -do- [Type here] PM/13428/3 January 2023 Test, Cl. 5.2.2 IS 5158(A-4)/ IS 9873(Part-6) Vibration Leakage Test, Cl. 5.2.3 IS 17753 R -do- Every 24 hours -do- Storage Test, Cl. 5.2.4 --- IS 8639 R -do- Every month -do- Water Vapour Transmission Rate (WVTR) and Oxygen Transmission Rate (OTR), Cl. 5.2.5 of IS 17753 IS 17753/ISO 2528(for WVTR) And ISO 15105-2(for OTR) R -do- Once in a fortnight -do- Print Resistance Test, Cl. 5.2.6 IS 17753 R -do- Every 24 hours -do- Ink Adhesion Test Cl. 5.2.7

Standard:IS 13428:2005
Gazetted SpecificationAnnex-E · clause 5.1
Official Gazette Text

IS 17753 R -do- Every 24 hours -do- Note-1: Whether test equipment is required or sub-contracting is permitted in column 2 shall be decided by the Bureau and shall be mandatory. Sub-contracting is permitted to a laboratory recognized by the Bureau or Government laboratories empaneled by the Bureau. Note-2: Levels of control given in column 3 are only recommendatory in nature. The manufacturer may define the control unit/batch/lot and submit his own levels of control in column 3 with proper justification for the approval by BO Head [Type here] PM/13428/3 January 2023 TABLE 5 Levels of control for Aluminium Cans for Packaged Natural Mineral Water and Packaged Drinking Water — Specification as per [Doc. No.: PGD 38(20182)] TEST DETAILS Test equipment LEVELS OF CONTROL Requirement Test Method requirement Lot size Remarks (Modes of Conformity etc.) R: required (or)S: No. of Clause Reference Sub-contracting Samples permitted Material, Cl. 5.1 5.1 IS 504 (Part 1 to 12) and IS 504 (Part 13 to 16) S One Each consignment of paper based multilayer composite sheet i) Test Reports from BIS recognized outside laboratory, OR ii) Test certificate issued by supplier. Temper, Cl. 5.2 --- IS 16983/IS 1776/ IS 12999 S One Each consignment i) Test Reports from BIS recognized outside

Standard:IS 13428:2005
Gazetted SpecificationAnnex-E · clause 5.3
Official Gazette Text

laboratory, OR ii) Test certificate issued by supplier Mechanical properties of the alloys for the body and closure, Cl. 5.3 --- IS 2508/IS 14500/ IS 10146/ IS 16738 S One Each consignment i) Test Reports from BIS recognized outside laboratory, OR ii) Test certificate issued by supplier Can bod, Cl. 6.1.1 6.1.1 PGD 38(20182) By visual Can Ends Cl. 6.1.2 6.1.2 PGD 38(20182) S One Each consignment i) Test Reports from BIS recognized outside laboratory, OR ii) Test certificate issued by supplier Internal finish Cl. 6.2 6.2 PGD 38(20182) By visual a) External Coating Cl. 6.3 b) Bottom Rim Coating Cl. 6.1.3 a) 6.3 b) 6.1.3 PGD 38(20182) S One Each consignment i) Test Reports from BIS recognized outside laboratory, OR ii) Test certificate issued by supplier a) Shape and Dimension b) Wall thickness Cl. 6.4.1 Table 3 PGD 38(20182) S One Each consignment i)Test Reports from BIS recognized outside laboratory, OR ii) Test certificate issued by supplier Shape and nominal dimension of closure Table 4 PGD 38(20182) S One Each consignment i) Test Reports from BIS recognized outside laboratory, OR [Type here] PM/13428/3 January 2023 components Cl. 6.4.2 ii) Test certificate issued by supplier

Standard:IS 13428:2005
Gazetted SpecificationAnnex-E · clause 7.1.1
Official Gazette Text

Top Load / Axial Load / Column Strength Cl. 7.1.1 7.1.1 PGD 38(20182) S One Each consignment i) Test Reports from BIS recognized outside laboratory, OR ii) Test certificate issued by supplier Enamel Rater Criteria Cl. 7.1.2 7.1.2 PGD 38(20182) S One Each consignment i) Test Reports from BIS recognized outside laboratory, OR ii) Test certificate issued by supplier Air Pressure Test Cl. 7.1.3 --- IS 2471 S One Each consignment i) Test Reports from BIS recognized outside laboratory, OR ii) Test certificate issued by supplier Slip Angle Test / Wall Mobility Test Cl. 7.1.4

Standard:IS 13428:2005
Gazetted SpecificationAnnex H
Official Gazette Text

operations? ii) Plant and Physical Facilities a) Is adequate lighting provided at working station, hand washing area, and storage areas? b) Are light fixtures safety type and protected to prevent contamination in the event of breakage in the processing and packing area? c) Are the processing areas well-ventilated, to minimize odours , noxious fumes and condensates? d) Are the barriers/traps provided at drains to prevent the entry of rodents from the drains into the facility? e) Is effective screening provided against entry of birds, animals, insects, rodents, etc f) Are doors, hatches and other openings to the building constructed to render opening pest proof? g) Are floors, walls, ceilings, windows and doors so designed and constructed as to render them washable? h) Is product in process and storage area adequately protected from any leakage from external surfaces and other sources of contamination? i) Are immediate surroundings of extraction or collection protected from entry of unauthorized persons? iii) Raw Water Processing a) In case of extraction/collection for processing are the sources free

Standard:IS 13428:2005
Gazetted SpecificationAnnex-B PGD 38(20182) S One Each consignment i) Test Reports from BIS recognized outside · clause 7.2
Official Gazette Text

laboratory, OR ii) Test certificate issued by supplier Testing of Ends Cl. 7.2 7.2 PGD 38(20182) S One Each consignment i) Test Reports from BIS recognized outside laboratory, OR ii) Test certificate issued by supplier Overall Migration Limit Cl. 7.3.1 --- IS 9845 S One Each consignment i) Test Reports from BIS recognized outside laboratory, OR ii) Test certificate issued by supplier Specific Migration Limit Cl. 7.3.2 --- IS 9845 S One Each consignment i) Test Reports from BIS recognized outside laboratory, OR ii) Test certificate issued by supplier Water Potability Test Cl. 7.4 --- IS 2500(Part-1) S One Each consignment i) Test Reports from BIS recognized outside laboratory, OR ii) Test certificate issued by supplier Note-1: Whether test equipment is required or sub-contracting is permitted in column 2 shall be decided by the Bureau and shall be mandatory. Sub-contracting is permitted to a laboratory recognized by the Bureau or Government laboratories empaneled by the Bureau. Note-2: Levels of control given in column 3 are only recommendatory in nature. The manufacturer may define the control unit/batch/lot and submit his own levels of control in column 3 with proper justification for the approval by BO Head PM/13428/3 January 2023

Standard:IS 13428:2005
Gazetted SpecificationAnnex G · clause 2.1
Official Gazette Text

Guidelines for Special Situations G-1 Change of source of raw water or change in process As and when there is change in source water, it shall be intimated to BIS. The raw water collected from the new source shall be tested in accordance with Clause 7 of SIT and the processed water produced from such source water shall be tested for conformity to IS 13428 from BIS recognized outside lab. The reports of source water and the product water produced from the new source shall be submitted to BIS for approval before commissioning for regular production and marking. G-2 Modification in the process G-2.1 In case of any addition, alteration and/or change in the production process without any change in raw water source, the processed water produced from such changed process shall be tested for conformity to IS 13428 from BIS recognized outside lab. The reports of the product water produced from the changed process shall be submitted to BIS for approval before commissioning for regular production and marking. G-2.2 Testing of product water so produced by using different processes shall be carried out as per SIT and records be kept separately by the licensee.

Standard:IS 13428:2005
Gazetted SpecificationAnnex G · clause 3.1
Official Gazette Text

Note 1: Testing for parameters concerning radio-active residues need not be done under above circumstances provided the source of raw water remains the same. Note 2: Any change in process may require change of label. Therefore licensee may be advised to prepare fresh label incorporating all marking details. G-3 Shelf-life G-3.1 Declared shelf life for Natural Mineral Water in all type of packing materials shall not be less than 30 days. If the manufacturer intends to declare a longer shelf-life than minimum 30 days, study shall be conducted on each type of packing whenever there is a change in the source of raw water/manufacturing/packing process, whichever is earlier. The shelf-life shall be declared on the labels as per 8.1 (g) of IS 13428. It shall be based on in-house shelf life study for which proper records be maintained conforming to declared shelf life. G-3.2 Subsequently, for any change in the shelf life declared on the labels, the manufacturer shall inform BIS in advance along with shelf- life study reports and submit fresh label for approval. Tests to be carried out for shelf life studies are requirements given in Table 1 of IS 13428 along with routine microbiological tests as per IS 13428.

Standard:IS 13428:2005
Gazetted SpecificationAnnex G · clause 4.2
Official Gazette Text

G-4 Label/marking approvals G-4.1There is a practice that applicants/licensees submit labels to BIS for approval. Wherever any applicant/licensee submits labels to BIS for approval, it shall be informed to them that the labels conforming to the marking details as mentioned in clause 8 of IS 13428 along with the brand names are to be submitted PM/13428/3 January 2023 to by licensees to BIS for information only, which will only be noted by BIS for records. G-4.2 The compliance of such labels to the requirement of clause 8 shall be ensured by licensees. However, in case non-compliance to Clause 8 is observed by BIS and communicated in writing (provided brand name/trademark is not registered) to licensee, licensee shall make necessary rectification and resubmit the label for confirmation to concerned BIS Branch Office within 15 days. Decision of BIS regarding whether labeling is complying or not with clause 8 of IS 13428 shall be final. G-4.3 However, in case the brand name/trademark submitted by the firm is a registered brand name/trademark, no objection to its use shall be raised even if the brand name/trademark is found to be in non-compliance to Clause 8. However, in such a case, the Head BO concerned shall communicate the details of such cases to CMD-2 for taking up with the concerned authorities. PM/13428/3 January 2023

Standard:IS 13428:2005
Gazetted SpecificationAnnex H
Official Gazette Text

CHECKLIST FOR GOOD HYGIENE PRACTICES AND FOOD SAFETY SYSTEMS FOR PACKAGED NATURAL MINERAL WATER PROCESSING UNITS SI No. Requirements (1) (2) Answers Remarks (5) Adequate (3) Not Adequate (4) i) Building, Facilities and Locations a) Is the facility location area free from objectionable odour, smoke, dust or other contaminants and not subject to flooding? b) Are the areas immediately surrounding the buildings, roads, packing places, suitably paved, grassed and kept clean? c) Is adequate facility for drainage of surroundings available and is designed to handle peak load? d) Is the facility used for processing water, free from Domestic animals? e) Is the facility surroundings free from refuse, waste materials, rubbish, overgrown weeds and grasses? f) Are there adequate facilities for the disposal of effluents and wastes? g) Are the buildings and facilities of sound construction and maintained in good repair? h) Are the buildings and facilities designed and maintained to prevent entrance and harboring of pests and entry of contaminants? i) Are building and facilities designed to facilitate Hygienic

Standard:IS 13428:2005
Gazetted SpecificationAnnex H
Official Gazette Text

from contaminations/ impurities? PM/13428/3 January 2023 b) Are water storage tanks, pipe lines utilized for handling water constructed and so designed as to facilitate cleaning and inspection? c) Are inspections of containers/carriers/pipe lines of raw water supply performed for the material of construction and cleanliness? d) Are possible chances of contamination from incoming water assessed? e) Are water storage tanks regularly cleaned and records maintained to prevent entry of pests and potential contaminator? f) Are the processed water contact surfaces regularly cleaned and sanitized and records maintained? iv) Post-processing Handling a) Are cleaning operation of bottles/containers so done as to preclude contamination of product and product contact services with residues? b) Has absence of residual cleaning chemicals been ensured? c) Is preventive maintenance in place for all processing machinery and equipment? d) Are the primary packing materials and containers of food grade conforming to relevant Indian Standards? e) Are packing and sealing, where required, monitored? f) Are physical hazards prevented from entering into processed water?

Standard:IS 13428:2005
Gazetted SpecificationAnnex H
Official Gazette Text

g) Are glassware excluded from production area? v) Packaging Material and Finished Goods Storage a) Are the primary packing materials and containers of food grade conforming to relevant Indian Standards? b) Are the packaging materials inspected to ensure their suitability? c) Are the packing materials especially primary packing material properly stored and properly handled to preclude contamination? d) Are the packaging materials purchased, stored and handled in sanitary manner? vi) Finished Product Storage and Distribution a) Is first-in-first out (FIFO) of stored product maintained? b) Is storage properly sanitized and disinfected periodically? c) Are stores protected from pest infestations? d) Are coding and tracking clear and in place? e) Are the instruction clear and in place? f) Are hold/release procedure in place and product identified? g) Are the records maintained for batch number, date of and volume of production? h) Are transport containers/vehicles maintained in clean condition? vii) Customer Handling of Products a) Are the storage instructions provided on containers? b) Is the shelf life period/best before mentioned on containers ? c) Are instructions provided for handling defective/damaged products?

Standard:IS 13428:2005
Gazetted SpecificationAnnex H
Official Gazette Text

viii) Sanitary Facilities and Control a) Are toilets provided in sufficient numbers and are they provided with: 1) Doors of self-closing type? 2) Do not open directly into processing areas? 3) Hand washing signs provided in appropriate language? PM/13428/3 January 2023 4) Proper lighting and ventilation? 5) Proper maintenance to keep in clean and tidy manner? b) Are hand washing facilities provided adequately and conveniently to wash hands, foot, elbow or sensor operated taps? c) Are germicidal soaps/soap solution and hand drying facility provided? d) Are notice/ instructions prominently pasted in toilet directing employees to wash their hands on entry and re-entry into the packaged drinking water handling areas? e) Are the refuse receptacles self closing type maintained in a manner to protect from contaminations? ix) Personnel Hygiene and Habits a) Is any individual assigned to supervise overall sanitation of plant and personnel? b) Is there any person responsible for day-to-day monitoring of health and hygiene? c) Are the medical records of the employees in processing, packing and maintenance been periodically maintained?

Standard:IS 13428:2005
Gazetted SpecificationAnnex H
Official Gazette Text

d) Are the personnel with infectious diseases, skin infection and open lesion or any other source of microbial contamination excluded from working in process/packing areas? e) Are the following personnel hygiene practices regularly maintained and monitored: 1) Clean outer garments- protective clothing? 2) Personal cleanliness-finger nails? 3) Head cover-hair restraints, caps, head bands, beard cover? 4) No tobacco in any form-smoking, chewing? 5) No eating at work stations? f) Are protective clothing stored on the premises and not allowed to be used for outside wear? g) Are there clear legible notices defining limits of no smoking areas such as ‘NO SMOKING BEYOND THIS POINT’ displayed? h) Have the personnel been imparted training or hygienic food handling, processing food and personal hygiene? i) Are unsecured jewellery and other objects such as wrist watches, cufflinks, ear rings, glass bangles, stick BINDIS removed at work? CONCLUSION: OVERALL ASSESSMENT OF HYGIENIC CONDITIONS – SATISFACTORY/ NOT SATISFACTORY

Standard:IS 13428:2005
04

Dossier Provenance & Verification Record

Record Source:BIS
Verification Status:Verified Record
Ingestion Checksum:e29495601f469b963365c4c74225c8cea481ef8df6d13a88035b620dfd62e5a2
Database Sync Timestamp:2026-09-03T12:48:01.544Z